Normal values for the size of a halo produced by a glare source.

نویسندگان

  • María C Puell
  • María J Pérez-Carrasco
  • Ana Barrio
  • Beatriz Antona
  • Catalina Palomo-Alvarez
چکیده

PURPOSE To determine the size of a halo in the visual field induced by bright light in healthy eyes of all ages using the Vision Monitor (MonCv3; Metrovision, Pérenchies, France) and to assess the repeatability of the method. METHODS Measurements were made in the right eyes of 147 healthy subjects (mean age: 48.2 ± 16.2 years) who were classified into six age groups. Using the Vision Monitor, optotypes of low luminance were presented at a distance of 2.5 m. The visual angle subtended by the radius of the halo was calculated in minutes of arc (arc min). The repeatability of the method was determined in a subset of 37 subjects older than 50 years by calculating the Bland-Altman coefficient of repeatability. RESULTS The mean radius of the halo was 111.6 ± 39.8 arc min. Halo radius started to increase significantly from the age of 50 to 59 years. The relationship between halo radius and age (r = 0.65; P < .0001) was described by fitting a power function to the data. Halo size was independent of gender. The coefficient of repeatability of the method was ±44 arc min. CONCLUSIONS Halo size increases with age following a power model. The normal halo size values provided could help clinicians distinguish between normal or abnormal glare problems. The intersession repeatability observed for halo size measurement indicates this method could be useful for assessing visual impairment caused by glare.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Relationship between halo size and forward light scatter.

PURPOSE To determine the relationship between the size of a halo induced by a glare source and forward scatter or visual acuity (VA) in healthy eyes. METHOD Measurements were made in the right eyes of 51 healthy individuals of mean age 29.3 ± 7.5 years. Halo radius was measured using the Vision Monitor and low luminance (1 cd/m(2)) optotypes presented at a distance of 2.5 m. The visual angle ...

متن کامل

بررسی اثر هاله ناخالصی کانال و شیب غلظت آن در ترانزیستور اثرمیدانی نانولوله کربنی با آلایش سبک ناحیه سورس و درین با هاله خطی

In this work, a lightly doped drain and source CNTFET with a linear channel impurity halo is proposed and the effect of linear halo slope variation on ON current, ON&ndash;OFF current ratio, leakage current, power&ndash;delay product (PDP) and cutoff frequency has been investigated. Proposed linear halo lightly doped drain and source CNTFETs has been simulated using non equilibrium Green&rsquo;...

متن کامل

Chemical Variation of Tourmaline and Source of Hydrothermal Solutions in Nezam Abad W-(Sn) Ore Deposit, Sanandaj-Sirjan Zone, West-Central Iran

Tourmalinization characterizes the most pervasive alteration type in the Nezam Abad ore deposit, west-central Iran. It delineates high-temperature centers of mineralization and together with quartz and cassiterite form inner parts of the alteration halo. The composition of tourmalines plots mostly along and between the proton and alkali-deficient end members. Tourmaline in quartzdioritic host i...

متن کامل

Halo size under distance and near conditions in refractive multifocal intraocular lenses.

AIMS To calculate the diameter of halos perceived by patients with multifocal intraocular lenses (IOLs) and to stimulate halos in patients with refractive multifocal IOLs in a clinical experiment. METHODS Calculations were done to show the diameter of halos in the case of the bifocal intraocular lens. 24 patients with a refractive multifocal IOLs and five patients with a monofocal IOL were as...

متن کامل

بررسی وضعیت کمی و کیفی روشنایی مرکز بهداشت شمیرانات بر اساس استاندارد EN 12464 -1

Introduction: Illumination standards especially Illumination Engineering Society of North America (IESNA) and Iran lighting standards (ILS) are just based quantitative measurements. However, lighting has psychological effects and can influence quality and quantity of productivity and comfort of workers. Therefore, Illumination standards were undergone some changes. EN 12464-1 standards focus on...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of refractive surgery

دوره 29 9  شماره 

صفحات  -

تاریخ انتشار 2013