Diffuse luminance flicker increases retinal vessel diameter in humans.
نویسندگان
چکیده
PURPOSE To determine retinal vessel diameter variations in response to neuronal activity induced by diffuse luminance flicker. METHODS The diameter of retinal arteries and veins was measured in 9 normal subjects by computer analysis of fundus pictures taken in monochromatic light under normal conditions of illumination and after 1 min of sinusoidally varying diffuse luminance flicker at 10 Hz. RESULTS The diameter immediately after flicker was significantly larger than the pre-stimulus diameter by 4.2 +/- 2.2% for the retinal arteries and 2.7 +/- 1.7% for the retinal veins (mean +/- SD). Six is after cessation of the flicker, arterial diameter was not significantly different from that of pre-flicker value. CONCLUSIONS Diffuse luminance flicker induces an increase in retinal vessel diameter. This increase most probably reflects an increase in retinal blood flow previously evidenced in humans by the blue field simulation technique. The technique needs to be optimized in terms of flicker parameters, to determine whether flicker-evoked retinal diameter changes could represent a useful clinical measure of the capability of the retinal vascular system to vasodilate.
منابع مشابه
Diffuse luminance flicker increases blood flow in major retinal arteries and veins
It has been shown that diffuse luminance flicker increases optic nerve head blood flow. The current study has been performed to quantify changes in retinal blood flow during flicker stimulation. In a group of 11 healthy volunteers, red blood cell velocity and retinal vessel diameters were assessed with bi-directional laser Doppler velocimetry and the Zeiss retinal vessel analyzer before, during...
متن کاملShort-term increase of intraocular pressure does not alter the response of retinal and optic nerve head blood flow to flicker stimulation.
PURPOSE It has been shown that stimulation with diffuse luminance flicker induces vasodilatation in the human retina and increases optic nerve head (ONH) blood flow. The present study was designed to investigate the influence of a short-term increase in intraocular pressure on flicker-induced changes in ONH blood flow and retinal vessel diameters. METHODS In a group of 15 healthy volunteers, ...
متن کاملInfluence of flicker frequency on flicker-induced changes of retinal vessel diameter.
PURPOSE To investigate the effect of diffuse luminance flicker of different frequencies on retinal vessel diameter in the human eye. METHODS Nine healthy subjects participated in the study. A retinal vessel analyzer (RVA; Zeiss, Jena, Germany) was modified to allow for continuous measurement of vessel diameter during flicker stimulation. With this technique, the light used for measurement of ...
متن کاملEffects of dopamine on human retinal vessel diameter and its modulation during flicker stimulation.
We performed a randomized, subject-blinded, placebo and time-controlled, two-way crossover study in 12 healthy male subjects. Placebo or dopamine was administered on two separate study days. After saline infusion, dopamine hydrochloride was infused in three consecutive doses (5, 10, and 15 microg x kg(-1) x min(-1)). Plasma levels of dopamine were determined at each perfusion step. Arterial and...
متن کاملReduced response of retinal vessel diameters to flicker stimulation in patients with diabetes.
BACKGROUND/AIM Stimulation of the retina with flickering light increases retinal arterial and venous diameters in animals and humans, indicating a tight coupling between neural activity and blood flow. The aim of the present study was to investigate whether this response is altered in patients with insulin dependent diabetes mellitus. METHODS 26 patients with diabetes mellitus with no or mild...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Current eye research
دوره 16 12 شماره
صفحات -
تاریخ انتشار 1997