Cost-benefit analysis and prediction of 24-hour proteinuria from the spot urine protein-creatinine ratio.

نویسندگان

  • V C Chitalia
  • J Kothari
  • E J Wells
  • J H Livesey
  • R A Robson
  • M Searle
  • K L Lynn
چکیده

AIM A prospective cross-sectional study was performed on 170 patients with various glomerular diseases to study the accuracy of predicting 24-hour proteinuria from the spot urine protein-creatinine ratio (Up/Uc). A cost-benefit analysis was performed for the New Zealand health economic system to obtain the best cut-off values for proteinuria. SUBJECTS, METHODS AND RESULTS Two spot urine samples (Up/Uc1 and Up/Uc2) were collected on the same day as the collection of a 24-hour urine. A randomly chosen subsample of 50 patients provided a second set of urine samples. The correlation and precision of agreement between the two methods were examined. The predictive intervals were calculated for derived 24-hour proteinuria. The level of agreement was evaluated by the Bland-Altman method and concordance analysis. The limits of agreement were evaluated against the clinical limits of agreement. A cost-benefit analysis (CBA) was performed to obtain the optimum operating points on receiver operating characteristic (ROC) curves for the best decision threshold. Correlations of r = 0.97 and 0.99 were observed between Up/Uc1, Up/Uc2 and 24-hour proteinuria, respectively. The 95% predictive intervals were wide. A high concordance correlation coefficient was obtained. The most of the differences between the two methods fell within the clinical limits of agreement. The Up/Uc1 of 0.26 and 3.20 represent the best thresholds to detect normal and nephrotic proteinuria, respectively. CONCLUSIONS Despite wide confidence intervals, a good correlation and precision of agreement were demonstrated between the two methods across the whole range of proteinuria, regardless of the level of renal function. The difference between the two methods was less than the biological variability in the protein excretion and its measurement, enabling the methods to be used interchangeably. The optimum thresholds for abnormal and nephrotic range proteinuria were obtained.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of spot urine protein creatinine ratio with 24 hour urine protein for estimation of proteinuria.

The objective of our study was to evaluate and standardise the method of spot (random) urine protein creatinine ratio (UP/C) for estimation of proteinuria. The study contained 241 study participants in a tertiary care hospital inclusive of 208 cases and 33 normal volunteers. The 24 hour urine protein estimation was done on 24 hour urine samples and UP/C ratio was calculated on random urine samp...

متن کامل

A look at risk factors of proteinuria in subjects without impaired renal filtration function in a general population in Owerri, Nigeria

INTRODUCTION Proteinuria is a common marker of kidney damage. This study aimed at determining predictors of proteinuria in subjects without impaired renal filtration function in Owerri, Nigeria. METHODS This was a cross-sectional study involving 136 subjects, consecutively drawn from Federal Medical Centre (FMC), Owerri, Nigeria. Relevant investigations were performed, including 24-hour urine...

متن کامل

A comparison of spot urine protein-creatinine ratio with 24-hour urine protein excretion in women with preeclampsia.

INTRODUCTION Proteinuria is an important diagnostic component of preeclampsia. We prospectively compared the results of spot urine protein-creatinine (P/C) ratio with 24-hour urine protein excretion in women with preeclampsia. MATERIALS AND METHODS A total of 81 pregnant women with preeclampsia were prospectively studied for proteinuria. Urine P/C ratio was determined in a spot mid-stream uri...

متن کامل

Spot urinary protein/osmolality ratio as a predictor for proteinuria of nephrotic range.

A prospective study was carried out on 50 patients (age 1-15 years) with nephrotic range of proteinuria to determine the correlation of 24-hour urinary total protein with spot urinary protein/creatinine ratio and urinary protein/osmolality ratio. Another 50 patients having no proteinuria grouped as control. Twenty-four hours urine and spot urine were collected from each child and were analyzed ...

متن کامل

Diagnostic accuracy of spot urine protein-to-creatinine ratio for proteinuria and its association with adverse pregnancy outcomes in Chinese pregnant patients with pre-eclampsia.

INTRODUCTION International guidelines have endorsed spot urine protein-to-creatinine ratio of >30 mg protein/mmol creatinine as an alternative to a 24-hour urine sample to represent significant proteinuria. This study aimed to determine the accuracy of spot urine protein-to-creatinine ratio in predicting significant proteinuria and adverse pregnancy outcome. METHODS This case series was condu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical nephrology

دوره 55 6  شماره 

صفحات  -

تاریخ انتشار 2001