Non-linear regularized decomposition of spectral x-ray projection images
نویسندگان
چکیده
Spectral computed tomography (CT) exploits measurements from x-rays with different energies to obtain the 3D description of the patient in a material basis. It requires to solve two subproblems, namely the material decomposition and the tomographic reconstruction problems, either sequentially or jointly. In this work, we address the material decomposition problem, which an ill-posed non-linear problem. Our main contribution is to introduce a material-dependent spatial regularization scheme. The problem is solved iteratively using the Gauss-Newton’s method. The framework is validated on numerical experiments of a thorax phantom made of soft tissue, bone and gadolinium scanned with a 90 kV source and a 3-bin photon counting detector.
منابع مشابه
Cartesian decomposition of matrices and some norm inequalities
Let X be an n-square complex matrix with the Cartesian decomposition X = A + i B, where A and B are n times n Hermitian matrices. It is known that $Vert X Vert_p^2 leq 2(Vert A Vert_p^2 + Vert B Vert_p^2)$, where $p geq 2$ and $Vert . Vert_p$ is the Schatten p-norm. In this paper, this inequality and some of its improvements ...
متن کاملApplication of Spectral Analysis in Mapping Hydrothermal Alteration of the Northwestern Part of the Kerman Cenozoic Magmatic Arc, Iran
The northwestern part of the Kerman Cenozoic magmatic arc (KCMA) contains many areas with porphyry copper mineralization. In this research, we used the advanced space-borne thermal emission and reflection radiometer (ASTER) and Enhanced Thematic Mapper plus (ETM+) images of this region to map the distribution of hydrothermally altered rocks, based on their mineral assemblages. The spectral meas...
متن کاملComparisons of Hounsfield Unit Linearity between Images Reconstructed using an Adaptive Iterative Dose Reduction (AIDR) and a Filter Back-Projection (FBP) Techniques
Background: The HU linearity is an essential parameter in a quantitative imaging and the treatment planning systems of radiotherapy. Objective: This study aims to evaluate the linearity of Hounsfield unit (HU) in applying the adaptive iterative dose reduction (AIDR) on CT scanner and its comparison to the filtered back-projection (FBP).Material and Methods: In this experimental phan...
متن کاملDetection of zinc-lead mineralization and associated alteration in the Mehdiabad deposit, Yazd province, using ASTER and Landsat 8-OLI satellite images
The Mehdiabad zinc-lead deposit, which is located at the East of Mehriz city, is a carbonate-hosted ore deposit lying in the dolomitic rocks of Taft Formation. This deposit is composed of oxide-carbonate and sulfide ores. Different spectral processing techniques were applied to ASTER and Landsat 8-OLI multispectral images to detect different mineralization zones and associated alterations. In O...
متن کاملNumerical solution of the one dimensional non-linear Burgers equation using the Adomian decomposition method and the comparison between the modified Local Crank-Nicolson method and the VIM exact solution
The Burgers’ equation is a simplified form of the Navier-Stokes equations that very well represents their non-linear features. In this paper, numerical methods of the Adomian decomposition and the Modified Crank – Nicholson, used for solving the one-dimensional Burgers’ equation, have been compared. These numerical methods have also been compared with the analytical method. In contrast to...
متن کامل