Comparison of 4 Brands of Elastomeric Chains Based On Time Dependent Force Decay

نویسندگان

  • Abhik Sen
  • Abhirup Goswami
چکیده

Objectives: To compare the force decay rate of the four brands of elastomeric chain over time and finally establish a gradation of brands in terms of force degradation characteristics. Materials and Methods: In this study total of two hundred and forty elastics were used. It had elastics of the same size from four different manufacturers. The experiment was carried out in vivo. For each patient the interbracket distance is measured for all four quadrants.The total distance thus registerd is then divided into half and recorded for effective chain length to standardize the amount of stretch for each chain. Four brands of elastomeric chain then attached to the specific attachment in patients mouth using split mouth technique. The patient recalled and the sample collected at 24 th hour,after 10days of following the first sample collection,and 30 days after the second sample collection.One set of sample of specified length was collected at 0 hours at not stretched condition. The procedure is repeated for all the 15 patients.A total of 240 samples thus collected using the following method. An Instron universal testing machine was used to measure the force in newton exerted by the elastics. Results: The result reveals at 24 hours there is a massive loss of initial exerted force and for all the brands the loss of force ranged from 35-40%.At this specific time the brand that retains maximum amount of initial force is Plastic chain(AO) at the level of 63.48% while maximum degradation of force was found in ALASTIK(3M UNITEK) which retained only 59.92%.At 10 days maximum force retained by ALASTIK(3M UNITEK) at 51.83% while maximum degradation was found in Plastic chain(AO) with only 46.23%.At the end of 30 days the effective loss of initially expressed force appears to be almost at the same level of all the commercially available brands.However the study reveals the leading brand in maximum force retention was DYNA-LINK(G&H) which retained 40.8% while Plastic chain(AO) was found to have lost the maximum force and retained only 39.63%. Conclusions: The conclusion suggests Plastic chain(AO) retains the highest amount of its initial force in percentage at the end of 24 hours but Between the time period of 24 hours and 10 days ALASTIK(3M UNITEK) loses the minimum amount of force in percentage among all brands.However it is DYNA-LINK(G&H) which showed the highest amount of retained average force compared to its initial force in percentage and exhibited a degradation performance which is more stable than the other brands.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparing the elastomeric behavior and force degradation pattern between different orthodontic elastomeric chains

Background and Aims: Elastomeric chains are known as a current device with the purpose of dental movement in orthodontic treatments. The aim of this study was to compare the elastomeric behavior and force degradation rate between different elastomeric chains existing in Iran in different time durations. Materials and Methods: 11 different elastomeric chains used in this study were: Class One, ...

متن کامل

Force-Degradation Pattern of Six Different Orthodontic Elastomeric Chains

OBJECTIVE An ideal orthodontic force system should exert continuous light force. Thus, many efforts have been made to improve the memory characteristics of elastomeric chains. The aim of this study was to compare elastomeric chains (ECs) claimed by their manufacturers to offer high memory with traditional ones according to their force-extension diagrams. MATERIALS AND METHODS In this in-vitro...

متن کامل

Force decay evaluation of thermoplastic and thermoset elastomeric chains: A mechanical design comparison.

OBJECTIVES To compare the following over a period of 8 weeks: (1) force decay between thermoplastic (TP) and thermoset (TS) elastomeric chains; (2) force decay between light (200-g) and heavy (350-g) initial forces; and (3) force decay between direct chains and chain loops (stretched from one pin around the second pin and back to the first pin). MATERIALS AND METHODS TP and TS chains were obt...

متن کامل

Evaluation of the effects of three different mouthwashes on the force decay of orthodontic chains

BACKGROUND Elastomeric chains are commonly used in orthodontics. Force decay in these materials poses clinical problems. The aim of this study was to evaluate the effects of three different mouthwashes on the force decay of orthodontic chains. MATERIALS AND METHODS In this experimental study, elastomeric chains with two different configurations were divided into eight groups (two control and ...

متن کامل

In vitro evaluation of force degradation of elastomeric chains used in orthodontics.

OBJECTIVE To analyze the in vitro force degradation of four different brands of elastomeric chains: American Orthodontics, Morelli, Ormco and TP Orthodontics. METHODS The sample consisted of 80 gray elastomeric chains that were divided into four groups according to their respective manufacturers. Chain stretching was standardized at 21 mm with initial force release ranging from 300 g to 370 g...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015