Difficult Laryngeal Mask Airway Placement.

نویسندگان

  • Aslı Demir
  • Eymen Gazel
  • Onur Açıkgöz
  • Ümit Karadeniz
چکیده

Laryngeal mask airway (LMA), which consists of a silicone tube connected to a miniature silicone mask appropriate for the shape of hypopharynx and covers the larynx as a gasket, was developed in 1980s in the United Kingdom. It is frequently used both to avoid negative effects of endotracheal intubation by establishing direct connection with the airway of patient and to easily provide a more reliable airway as compared to the facial mask. It has particular importance in difficult airway management and cardiopulmonary resuscitation since it can be successfully placed even by inexperienced users. Gel is applied to the posterior surface of the mask and it is placed blindly into the airway by pushing towards hypopharynx while the head of the patient is in extension position. Herein, we present a case, in which LMA could not be placed despite several attempts and a mass tissue was detected in the hypopharynx during laryngoscopy performed subsequently.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Laryngeal mask placement in a teaching institution: analysis of difficult placements

BACKGROUND Laryngeal mask airway (LMA) placement is now considered a common airway management practice. Although there are many studies which focus on various airway techniques, research regarding difficult LMA placement is limited, particularly for anesthesiologist trainees. In our retrospective analysis we tried to identify predictive factors of difficult LMA placement in an academic training...

متن کامل

Limitation of Laryngeal Mask Airway Usage in Open-Neck Procedure

I read the manuscript entitled “Case Report of An Open Neck Procedure Complication Associated with Laryngeal Mask Airway Use” by Subramaniam T et al. This is a valuable manuscript describing iatrogenic complications during level-2 cervical lymph node biopsy, in which the airway is managed with laryngeal mask airway (LMA). During the procedure, the surgeon realized that the mass was actually the...

متن کامل

Cricoid pressure impedes placement of the laryngeal mask airway and subsequent tracheal intubation through the mask.

We have studied 40 patients to see if cricoid pressure affects the success rate of ventilation through, and the position of, the laryngeal mask and subsequent fiberscope-aided tracheal intubation. Adequate ventilation of the lungs was produced through the laryngeal mask in 19 of 20 patients in the control group, but in only 10 of 20 patients in the cricoid pressure group (P < 0.002). The laryng...

متن کامل

Case Report of an open Neck Procedure Complication Associated with Laryngeal Mask Airway Use

Introduction: The laryngeal mask airway (LMA) is a safe method to establish airway control during general anaesthesia. In otolaryngology surgery, the use of a LMA is well established in ear surgery; however, the use of a LMA during open neck procedures remains controversial. We report a case in which the pharyngeal distortion by the LMA cuff resulted in an iatrogenic complication.   Case Report...

متن کامل

Hemodynamic responses to insertion of the laryngeal mask airway versus Combitube

Introduction: One of the most common problems during laryngoscopy involves sympathetic system stimulation and the subsequent hemodynamic changes. It is a key measure to maintain the hemodynamic stability of patients with cardiovascular diseases during induction of anesthesia. This study attempted to compare the hemodynamic effects of laryngeal mask airway and combitube. Methods: This prospec...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Turkish journal of anaesthesiology and reanimation

دوره 42 3  شماره 

صفحات  -

تاریخ انتشار 2014