Registration of renal SPECT and 2.5D US images
نویسندگان
چکیده
Image registration is the process of transforming different image data sets of an object into the same coordinate system. This is a relevant task in the field of medical imaging; one of its objectives is to combine information from different imaging modalities. The main goal of this study is the registration of renal SPECT (Single Photon Emission Computerized Tomography) images and a sparse set of ultrasound slices (2.5D US), combining functional and anatomical information. Registration is performed after kidney segmentation in both image types. The SPECT segmentation is achieved using a deformable model based on a simplex mesh. The 2.5D US image segmentation is carried out in each of the 2D slices employing a deformable contour and Gabor filters to capture multi-scale image features. Moreover, a renal medulla detection method was developed to improve the US segmentation. A nonlinear optimization algorithm is used for the registration. In this process, movements caused by patient breathing during US image acquisition are also corrected. Only a few reports describe registration between SPECT images and a sparse set of US slices of the kidney, and they usually employ an optical localizer, unlike our method, that performs movement correction using information only from the SPECT and US images. Moreover, it does not require simultaneous acquisition of both image types. The registration method and both segmentations were evaluated separately. The SPECT segmentation was evaluated qualitatively by medical experts, obtaining a score of 5 over a scale from 1 to 5, where 5 represents a perfect segmentation. The 2.5D US segmentation was evaluated quantitatively, by comparing our method with an expert manual segmentation, and obtaining an average error of 3.3mm. The registration was evaluated quantitatively and qualitatively. Quantitatively the distance between the manual segmentation of the US images and the model extracted from the SPECT image was measured, obtaining an average distance of 1.07 pixels on 7 exams. The qualitative evaluation was carried out by a group of physicians who assessed the perceived clinical usefulness of the image registration, rating each registration on a scale from 1 to 5. The average score obtained was 4.1, i.e. relevantly useful for medical purposes.
منابع مشابه
Quantitative SPECT and planar 32P bremsstrahlung imaging for dosimetry purpose –An experimental phantom study
Background: In this study, Quantitative 32P bremsstrahlung planar and SPECT imaging and consequent dose assessment were carried out as a comprehensive phantom study to define an appropriate method for accurate Dosimetry in clinical practice. Materials and Methods: CT, planar and SPECT bremsstrahlung images of Jaszczak phantom containing a known activity of 32P were acquired. In addition, Phanto...
متن کاملFusion and display of 3D SPECT and MR images registered by a surface fitting method
Since 3D medical images such as SPECT and MRI are taken under different patients positioning and imaging parameters, interpretation of them, as reconstructed originally, does not provide an easy and accurate understanding of similarities and differences between them. The problem becomes more crucial where a clinician would like to map accurately region of interest from one study to the ot...
متن کاملEvaluation of attenuation correction process in cardiac SPECT images
Introduction: Attenuation correction is a useful process for improving myocardial perfusion SPECT and is dependent on activity and distribution of attenuation coefficients in the body (attenuation map). Attenuation artifacts are a common problem in myocardial perfusion SPECT. The aim of this study was to compare the effect of attenuation correction using different a...
متن کاملHepatobiliary excretion of 99mTc-EC: A potential source of mistake in the interpretation of renal scintigraphy
A 10-year-old boy with a history of bloody discoloration of urine following recent appendectomy was referred to our department for urinary leakage/fistula evaluation. A renal Technetium-99m-L,L-ethylenedicysteine (99mTc-EC) scintigraphy was performed. After injection of radiotracer, a focus of activity appeared in the supralateral part of the right kidney which was confirmed as accum...
متن کاملDiagnostic dilemma of ectopic pelvic kidney in planar skeletal and renal cortical scintigraphy resolved by SPECT/CT
We present a 55-year old male patient who was subjected to whole body skeletal scintigraphy for metastatic work up of urinary bladder cancer. Whole body 99mTc-methylene diphosphonate (MDP) skeletal scintigraphy was performed. That revealed no skeletal metastasis in the entire body skeleton and normally visualized left kidney with empty right renal fossa. Additionally tracer activity ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Computerized medical imaging and graphics : the official journal of the Computerized Medical Imaging Society
دوره 35 4 شماره
صفحات -
تاریخ انتشار 2011