Corneal acidosis during contact lens wear: effects of hypoxia and CO2.

نویسندگان

  • J A Bonanno
  • K A Polse
چکیده

The effects of tear-film hypoxia and contact lens wear on human in vivo stromal pH was tested using a non-invasive fluorometric technique. Hypoxia was produced by exposing the normal open eye to 100% nitrogen gas passed through tight-fitting goggles. Stromal pH dropped from 7.53 +/- 0.02 to 7.34 +/- 0.03 (n = 12, +/- SD) within 90 min of nitrogen gas exposure, t1/2 = 20 min. After removing the goggles, stromal pH returned to baseline in 35 min, t1/2 = 10 min. Wearing a thick hydrogel contact lens which caused a tear PO2 less than or equal to 2 mm Hg with the eyes open, reduced stromal pH from 7.55 +/- 0.02 to 7.15 +/- 0.04 (n = 12, +/- SD) in 80 min, t1/2 = 9.5 min. After removing the lens, baseline pH was reached in 40 min, t1/2 = 4.5 min. The stromal pH differences between hypoxia (N2 only) and contact lens wear were not due to differences in tear temperature between the two procedures (contact lens wear 32 +/- 1.5 degrees C, goggles 33 +/- 1.0 degrees C). However exposing the eye to 95% nitrogen-5% carbon dioxide reduced stromal pH to 7.16 +/- 0.05 (n = 7, +/- SD) in 80 min, t1/2 = 8 min, which was similar to that produced during contact lens wear. These experiments show that contact lens wear causes corneal acidosis by: (1) the production of protons from hypoxic metabolism, and (2) the accumulation of carbon dioxide behind the lens due to low lens CO2 transmissibility.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Corneal epithelial and aqueous humor acidification during in vivo contact lens wear in rabbits.

PURPOSE Based on contact lens-induced stromal acidification of the cornea, it has been suggested that the corneal epithelial and endothelial cells also become acidotic during contact lens wear. This alleged acidification may have a role in altered cell appearance and metabolism during contact lens wear. This study investigated the effects of anoxia, carbon dioxide retention, and contact lens ga...

متن کامل

Hypoxia, overnight wear, and tear stagnation effects on the corneal epithelium: data and proposed model.

PURPOSE : To explore the possible mechanisms that may lead to overnight contact lens-associated corneal morbidity by examining data from several corneal epithelial permeability experiments obtained under different environmental and lens fitting paradigms. METHODS : Epithelial permeability was assessed by using fluorometry to determine the fluorescein penetration rate from the tear film into t...

متن کامل

pH dependence of corneal oxygen consumption.

PURPOSE To determine whether corneal acidosis, which occurs during contact lens wear, alters corneal O2 consumption (QO2) and if so, whether increased ion transport activity could contribute to altered QO2 during acidosis. METHODS PO2 was measured, using the phosphorescence quenching of Pd-meso-tetra-(4-carboxyphenyl) porphine, in an airtight chamber that held a trephined rabbit cornea. The r...

متن کامل

Soft contact lens extended wear affects corneal epithelial permeability: hypoxic or mechanical etiology?

Contact lens extended wear increases the permeability of epithelium to sodium fluorescein (P(dc)). The exact mechanism is not known. However, changes in P(dc) likely result from either corneal hypoxia or mechanical trauma, or both. We explored the effects of one-night continuous wear with either high- or low-Dk/t soft lenses on P(dc). The results show that corneal epithelial barrier function de...

متن کامل

Estimation of corneal endothelial pump function in long-term contact lens wearers.

PURPOSE To study the effects of long-term contact lens wear on morphologic and physiologic properties of corneal endothelial cells. METHODS The endothelial permeability to fluorescein and the rate of corneal deswelling from hypoxia-induced edema were measured in 20 long-term (mean, 17+/-9 years; range, 5-33 years) contact lens wearers and 20 age-matched control subjects. From these data, the ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 28 9  شماره 

صفحات  -

تاریخ انتشار 1987