Comparison of Three Phakic Intraocular Lenses for Correction of Myopia

نویسندگان

  • Farid Karimian
  • Alireza Baradaran-Rafii
  • Seyed Javad Hashemian
  • Ali Hashemloo
  • Mohammad Ebrahim Jafari
  • Mehdi Yaseri
  • Elham Ghahari
  • Shadi Akbarian
چکیده

PURPOSE To compare the visual outcomes and complications of three different types of phakic intraocular lenses (PIOLs), for correction of moderate to high myopia. METHODS We reviewed 112 myopic eyes undergoing PIOL implantation using Artisan (40 eyes), Artiflex (36 eyes), and implantable collamer lens (ICL, 36 eyes). Best corrected visual acuity (BCVA), intraocular pressure (IOP), pachymetry, corneal endothelial cell (CEC) loss, and higher order aberrations (HOA) were compared. RESULTS Mean follow-up period was 30 ± 11 months. Preoperatively, spherical equivalent (SE) refractive error was -11.6 ± 3.7, -9.59 ± 1.97, and -12.3 ± 4.8 D in the Artisan, Artiflex and ICL groups, respectively. SE was comparable among the study groups at final follow-up (P = 0.237). Mean astigmatic reduction was 0.31 ± 0.72, 0.45 ± 0.62, and 0.0 ± 0.57 in the Artisan, Artiflex and ICL groups, respectively (P = 0.007). Emmetropia (±1 D) was achieved in 60%, 91.7% and 77.8% of eyes in the Artisan, Artiflex and ICL groups, respectively, the difference was significant between the Artisan and Artiflex groups (P = 0.017). BCVA improvement more than one line occurred in 25%, 19.4% and 38.9% of eyes (P = 0.158); pachymetric changes were minimal with no difference among the three groups (P = 0.754), and mean CEC loss was 10 ± 9%, 9 ± 6% and 9 ± 10% in the Artisan, Artiflex and ICL groups, respectively (P = 0.694). HOAs (P = 0.039), vertical trefoil (P = 0.032) and spherical aberration (P = 0.001) were higher with Artisan group as compared to ICL. Total aberrations (P = 0.028) and spherical aberration (P = 0.001) was also higher with Artisan group as compared to Artiflex. CONCLUSION Visual and refractive outcomes were comparable with Artisan, Artiflex and ICL. In terms of HOAs and quality of vision, ICL and Artiflex seem to be better choices in highly myopic eyes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

AcrySof Phakic IOL for Correction of Moderate-to-High Myopia: 1 Year Results

The implantation of a phakic intraocular lens (IOL) for the correction of moderate or high myopia has theoretical advantages in comparison with corneal procedures and clear lens extraction, such as precision and stability not dependent on the corneal healing process, a wider range of correction, magnification of the intraocular image, and preservation of accommodation. However, these lenses hav...

متن کامل

Correction of myopia of 7 to 24 diopters with the Artisan phakic intraocular lens: two-year follow-up.

PURPOSE To evaluate the safety and efficacy of the iris claw phakic intraocular lens (Artisan; Ophtec BV, Groningen, The Netherlands) in patients with high myopia. METHODS Between May 1999 and July 2001, 93 Artisan phakic intraocular lenses (IOLs) were implanted in 60 patients affected by high myopia. All patients underwent 24-month follow-up. The power of the lenses ranged from -7.5 to -22.0...

متن کامل

Iris-fixated phakic intraocular lens implantation for correction of high myopia in microspherophakia.

We report the refractive correction of high myopia in a 23-year-old patient with idiopathic microspherophakia using iris-fixated phakic intraocular lenses (pIOLs) (Verisyse/Artisan). Four years after bilateral implantation, the uncorrected distance visual acuity was 20/25 with a correction of 20/20(-1) in both eyes. No intraoperative or postoperative complications occurred. Iris-fixated pIOLs a...

متن کامل

Posterior chamber phakic intraocular lens implantation for high myopia.

OBJECTIVE To evaluate the efficacy, safety and stability of posterior chamber phakic intraocular lens (PIOLs) implantation for the correction of high myopia. METHODS Thirty-nine eyes of twenty patients with high myopia (between -11.75 and -25.75 diopters) had a posterior chamber PIOL (Staar ICL) implanted. During 6 - 48 months' follow-up, visual acuity, refraction, intraocular pressure (IOP),...

متن کامل

Excimer laser refractive surgery versus phakic intraocular lenses for the correction of moderate to high myopia.

BACKGROUND Myopia is a condition in which the focusing power (refraction) of the eye is greater than that required for clear distance vision. There are two main types of surgical correction for moderate to high myopia; excimer laser and phakic intraocular lenses (IOLs). Excimer laser refractive surgery for myopia works by removing corneal stroma to lessen the refractive power of the cornea and ...

متن کامل

Visual Improvement in High Myopic Amblyopic Adult Eyes following Phakic Anterior Chamber Intraocular Lens Implantation

PURPOSE To evaluate the efficacy and safety of angle-supported phakic anterior chamber intraocular lenses in amblyopic adult eyes with very high myopia. METHODS We evaluated 12 eyes in nine patients with very high myopic amblyopia who received angle-supported phakic intraocular lenses (Phakic 6H) and followed them for more than six months. Uncorrected visual acuity (UCVA), best-corrected visu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2014