Contemporary Oxygenator Design Relative to Hemolysis.
نویسندگان
چکیده
Hemolysis is a well-known phenomenon during cardiovascular surgery and generally attributed to cardiopulmonary bypass, particularly when using high-resistant oxygenators. This study aimed at investigating whether transoxygenator pressure drop can be considered an independent factor of hemolysis. Additionally, intraoxygenator blood distribution and shear stress were assessed. A low-resistant (LR, n = 3), a moderate-resistant (MR, n = 3), and a high-resistant (HR, n = 3) clinically used membrane oxygenator were tested in vitro using a roller pump and freshly drawn heparinized porcine blood. Flow rates were set to 2 and 4 L/min and maximum flow compliant to the oxygenator type for 1 hour each. As a control, the oxygenator was excluded from the system. Blood samples were taken every 30 minutes for plasma-free hemoglobin assay and transoxygenator pressure was measured inline. Intraoxygenator blood distribution was assessed using an ultrasound dilution technique. Despite the relatively broad spectrum of pressure drop and resultant transoxygenator pressure drops (LR: 14-41 mmHg, MR: 29-115 mmHg, HR: 77-284 mmHg, respectively), no significant association (R2 = .074, p = .22) was found with the normalized index of hemolysis. The shear stress of each oxygenator at maximum flow rate amounted to 3.0 N/m2 (LR), 5.7 N/m2 (MR), and 8.4 N/m2 (HR), respectively. Analysis of blood flow distribution curves (kurtosis and skewness) revealed intraoxygenator blood flow distribution to become more homogeneous when blood flow rates increased. Contemporary oxygenators were shown not to be a predominant factor for red blood cell damage.
منابع مشابه
New generation extracorporeal membrane oxygenation with MedTech Mag-Lev, a single-use, magnetically levitated, centrifugal blood pump: preclinical evaluation in calves.
We have evaluated the feasibility of a newly developed single-use, magnetically levitated centrifugal blood pump, MedTech Mag-Lev, in a 3-week extracorporeal membrane oxygenation (ECMO) study in calves against a Medtronic Bio-Pump BPX-80. A heparin- and silicone-coated polypropylene membrane oxygenator MERA NHP Excelung NSH-R was employed as an oxygenator. Six healthy male Holstein calves with ...
متن کاملAn in vitro protocol for evaluation and comparison of membrane oxygenators.
With the trend in open heart surgery toward normothermic bypass and warm blood cardioplegia, greater demand is being placed on the perfusionist to select an oxygenator that will perform safely and efficiently under a variety of conditions. While manufacturers report performance parameters for their products, the data is often not comparable due to widely differing conditions. Recent in vitro ...
متن کاملUsing anti-platelet therapy to prevent extracorporeal membrane oxygenator thrombosis without heparin resistance and with thrombocytopenia
Anticoagulation is widely used for preventing membrane oxygenator thrombosis during extracorporeal membrane oxygenation (ECMO) therapy while anti-platelets are rarely used, especially in patients with thrombocytopenia [1]. Here we report a case of successfully using anti-platelet treatment to prevent recurrent extracorporeal membrane oxygenator thrombosis in a fulminant myocarditis (FM) patient...
متن کاملThe Relationship Between Membrane Oxygenator Blood Path Pressure Drop and Hemolysis: An In-vitro Evaluation
Plasma hemoglobin (pl-Hgb) production was measured for the Bard HF-5000 (n = 4 ), Sams SMO (n =4) and Sams Turbo (n =4) membrane oxygenators (MO), which were tested on separate closed-loop roller pump circuits to compare differences in hemolysis production as a function of pressure drop (P). The three oxygenators were selected because of their varied P characteristics. Circuits were prepared by...
متن کاملImpact of hollow-fiber membrane surface area on oxygenator performance: Dideco D903 Avant versus a prototype with larger surface area.
This study compares the gas transfer capacity, the blood trauma, and the blood path resistance of the hollow-fiber membrane oxygenator Dideco D 903 with a surface area of 1.7 m2 (oxygenator 1.7) versus a prototype built on the same principles but with a surface area of 2 m2 (oxygenator 2). Six calves (mean body weight: 68.2 +/- 3.2 kg) were connected to cardiopulmonary bypass (CPB) by jugular v...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The journal of extra-corporeal technology
دوره 46 3 شماره
صفحات -
تاریخ انتشار 2014