Assessement of blood volume fraction using MRI: characterization in silico of possible bias
نویسندگان
چکیده
Introduction Several MR methods require a mathematical model of microvasculature to extract physiological parameters such as blood volume fraction (BVf), vessel size index (VSI) and blood oxygen saturation. In the case of BVf and VSI, MR estimates obtained in healthy and tumoral tissues – although well correlated with histology – seemed too large [1]. As tumoral development can strongly alter the geometrical characteristics of the microvascular network, the straight cylinder assumption generally made in MR simulations might become inadequate. In this study, we evaluate in silico how vessel density, vessel preferential orientation, vessel shape or curvature affect the MR estimate of BVf. To obtain, in silico, MR estimates of BVf from vessel networks that differed from combination of straight cylinders, we propose an original computation scheme based on [2] [3]. Material and methods The steady-state MR approach to measure BVf was simulated [4]. A cube of 125μm side length was considered (spatial sampling: 0.4μm). A diffusion coefficient (D=10ms) and a magnetic susceptibility – that of blood or of tissue – was associated to each point, using various vessel networks (common characteristics: BVf=3% and vessel radius=3μm, Fig. 1a). The magnetic field distribution was computed at 4.7T using a Fourier based approach [2] (Fig. 1b). Relaxation and diffusion of water were accounted for using a deterministic approach [3]. The MR signal (i.e. the gradient echo transverse magnetization as a function of echo time, Fig. 1c) was computed. In absence of contrast agent, blood and tissue susceptibility were considered as equal (i.e. the effect of O2 on the magnetic susceptibility is neglected). In presence of contrast agent, the blood susceptibility was 0.28ppm [4]. BVf,MR was eventually computed using: BVf,MR=3/(4π) ΔR2/(γΔχB0), were Δχ represent the change in blood susceptibility and γ the magnetogyric ratio for proton. Simulations were performed in the Matlab environment. BVf,MR estimates were first obtained on distributions of straight cylinders to evaluate whether our approach was able to accurately determine the BVf introduced into the simulation. Four types of simulations were then performed: i) Vessel shape was varied stepwise from straight to curved cylinder using a distribution of 900 cylinders with random orientations (no preferential orientation). ii) Vessel shape was varied between cylinders, ellipsoids and spheres using a distribution of 900 cylinders without preferential orientation. iii) The distribution of vessel orientation was varied between random distribution, 3 orientations (x, y, and z axes) with no preferential orientation, one preferential orientation (either parallel or perpendicular to B0). For the latter, the fraction of vessels with a preferential orientation (preferential orientation index, POi) was varied from perpendicular (POi=0) to parallel to B0 (POi= infinity). POi=(number of vessels parallel to B0) / (number of vessels perpendicular to B0 / 2). POi=1 corresponds to the absence of preferential orientation. iv) Vessel density was varied by increasing the inter-vessel distance from 22 to 43μm, using a distribution of 12 cylinders in the three principal orientations and without preferential orientation (POi=1). Results Using straight cylinders as a reference, the proposed simulation approach provides a BVf estimate with less than 2% error. Results of each simulation were: (i) Shape or curvature have minimal influence on results (<5%) except for the limit case of spherical shape (15%). (ii) Random and three direction distributions of vessel orientations (Fig. 2a) provide the same accurate estimates of BVf. A larger amount of vessels orientated perpendicularly to B0 yields a BVf overestimation (POi<1); a larger amount of vessels orientated along B0 (POi>1)(Fig. 2b) yields a BVf underestimation (Fig. 2c). (iv) For an intervessel distance of about 30μm (healthy gray matter value), BVf is overestimated by 20%. As intervessel distance increases from 22 to 43μm, BVf overestimation remains in the range of [23-14%] (Fig. 3c).
منابع مشابه
Effect of Bias in Contrast Agent Concentration Measurement on Estimated Pharmacokinetic Parameters in Brain Dynamic Contrast-Enhanced Magnetic Resonance Imaging Studies
Introduction: Pharmacokinetic (PK) modeling of dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) is widely applied in tumor diagnosis and treatment evaluation. Precision analysis of the estimated PK parameters is essential when they are used as a measure for therapy evaluation or treatment planning. In this study, the accuracy of PK parameters in brain DCE...
متن کاملSYNTHESIS, CHARACTERIZATION AND CATALYTIC BEHAVIOUR OF SPECIAL TYPE OF SILICO ALUMINO-PHOSPHATE WITH OPAL STRUCTURE
In this study a special type of silicoaluminophosphate with opal structure (Opal-SAPO) was prepared under microwave condition using tetraethylorthosilicate (TEOS), triethanolamine (TEA), aluminiumisopropoxid and phosphoric acid 85%. The product was characterized by X-ray diffraction (XRD), thermogravimetric (TGA) and Fourier Infrared Spectroscopy (FTIR).The crystalline product showed a good act...
متن کاملBlood volume fraction measurements using MRI: a correlation between two-photon and in silico MR estimates
Introduction Several MR methods allow quantification of microvascular characteristics such as blood volume, vessel size index [1] or blood oxygenation level [2]. Although these methods have shown good correlation with other techniques, the absolute quantification requires further investigation [3]. Recently, it has been shown that MR signal from complex microvascular networks could be obtained ...
متن کاملDT-MRI Tractography and its Application in Cognitive Neuroscience
Recent advancement of MRI techniques and development of new methods of image analysis have allowed us to study large neural tracts within the human brain. This is based on the principle of diffusion tensor MRI that is similar to that of diffusion-weighted imaging but takes magnitude and direction of the diffusion of water into account. Using this technique we have been able to define large neur...
متن کاملDT-MRI Tractography and its Application in Cognitive Neuroscience
Recent advancement of MRI techniques and development of new methods of image analysis have allowed us to study large neural tracts within the human brain. This is based on the principle of diffusion tensor MRI that is similar to that of diffusion-weighted imaging but takes magnitude and direction of the diffusion of water into account. Using this technique we have been able to define large neur...
متن کامل