The determination of tungsten in biological material by activation analysis.
نویسنده
چکیده
Tungsten exists at such low concentrations in normal biological material that it has been detected only in tissues from animals previously fed with unusually large quantities of tungsten (Kinard & Van de Erve, 1941), or plants growing in tungsten-rich soils (J. P. R. Polkinhorne, personal communication). In view of the discovery that the related element molybdenum is essential for plants and animals and is a constituent of at least two enzyme systems, it would seem that further measurements of tungsten might yield equally interesting results. The present note describes a technique capable of detecting as little as 1 itmg. of tungsten. The method used is that of activation analysis, which is now established as an extremely sensitive technique for determining trace elements in tissue (Loveridge & Smales, 1957; Bowen & Cawse, 1959). A number of workers have studied the distribution of tungsten in samples of geochemical and metallurgical interest by this technique (e.g. Atkins & Smales, 1959; Leliart, Hoste & Eeckhaut, 1959), and a recent paper describes the determination of the element in various marine organisms (Fukai & Meinke, 1959). Tungsten has a relatively high cross-section for thermal neutrons (much higher than that of molybdenum) and, among the radioactive isotopes produced, 24-hr. '57W is much the most abundant. In this work chemical methods were used to isolate the 187W activity from the other radioelements occurring in the activated material. Contamination before activation was minimized as described in the next section, and subsequent contamination would not affect the analysis.
منابع مشابه
Investigation of composite powder synthesis (Al2O3-WXSiY-WXBY) in aluminothermic combustion system (Al+B2O3+Si+WO3) using thermal analysis
Composites that are including silicide of tungsten and boride of tungsten intermetallic compound have properties such as high hardness, relatively good thermal shock, chemical stability and high strength at high temperature. The purpose of this investigation is evaluation of phase and microstructure of alumina base composite reinforced by boride and silicide of tungsten in three systems 1-Al+...
متن کاملHot tensile properties of 9Cr-2WVTa reduced-activation ferritic/martensitic steel
Reduced-activation ferritic/martensitic steels have been developed by replacing molybdenum by tungsten and niobium by tantalum in commercial elevated-temperature Cr–Mo steels to reduce half-life of radioactive isotopes. The objective of this study was to investigate tensile properties of a reduced-activation ferritic/martensitic steel (9Cr-2WVTa) in normalized-tempered (NT) and quenched-tempere...
متن کاملPreparation and Characterization of WO3 Electrochromic Films Obtained by the Sol-Gel Process
Tungsten trioxide (WO3) films have been coated on indium thin oxide (ITO) conductive glass substrate, using aqueous solution of peroxotungstic acid (PTA) by the sol-gel dip coating method. X-ray diffractometery (XRD) analysis confirmed monoclinic and triclinic structure for the film and powdered WO3 respectively. Fourier transforms infrared spectroscopy (FT-IR) exhibit...
متن کاملPartial Least Square and Parallel Factor Analysis Methods Applied for Spectrophotometric Determination of Cefixime in Pharmaceutical Formulations and Biological Fluid
In this study, the direct determination of cefixime as an anti-bacterial agent, in pharmaceutical formulations, urine and human blood plasma was conducted based on spectrophotometric measurements using parallel factor analysis (PARAFAC) and partial least squares (PLS). The calibration set was composed of fourteen solutions in the range of 0.50- 9.00 µg mL-1. PLS models were calculated at each p...
متن کاملPartial Least Square and Parallel Factor Analysis Methods Applied for Spectrophotometric Determination of Cefixime in Pharmaceutical Formulations and Biological Fluid
In this study, the direct determination of cefixime as an anti-bacterial agent, in pharmaceutical formulations, urine and human blood plasma was conducted based on spectrophotometric measurements using parallel factor analysis (PARAFAC) and partial least squares (PLS). The calibration set was composed of fourteen solutions in the range of 0.50- 9.00 µg mL-1. PLS models were calculated at each p...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Biochemical journal
دوره 77 1 شماره
صفحات -
تاریخ انتشار 1960