The role of elastography in improving detection rates of prostate cancer

نویسندگان

  • D. Badescu
  • Mihai Dumitrache
چکیده

Objectives: In this study we sought to evaluate whether elastography targeted biopsy improves the detection rate of PCa (prostate cancer) compared to systematic biopsy guided by conventional grayscale ultrasound (GSU). Materials and method: We conducted a prospective study and enrolled 240 patients on which we performed a 12 core prostate biopsy by conventional ultrasound guidence or elastography guided. The external prostate was divided into six sectors: base right, middle right, apex right, baseleft, middle left, apex left. These sectors were scanned for suspicious lesions by elastography – hard areas and by gray scale ultrasound hipoechoic areas. If in a certain sector a suspicious area was found, regardless of the imaging method, a single biopsy from this area was performed , whilst considering it representative for that certain sector. Imaging results were correlated with the results received from the pathologist lab. The two tools used in prostate biopsy guidance were compared statistically in terms of the detection rate of prostate cancer. We did not find statistical differences between the two groups concerning age, PSA (prostatic specific antigen), prostate volume, the data obtained by digital rectal examination. Prostate cancer was detected in 42.5% of patients (102 of 240). PCa detection rate was significantly higher in those who used elastography 51.6% (62 of 120) compared to those that have used conventional ultrasound 38.3% (46 of 120). elastography’ssensitivity was 56.8% compared to 17.5% for conventional ultrasound. Specificity was 70.7% compared to 92.8% for elastography to conventional ultrasound. Conclusions: Using elastography in prostate biopsy has higher sensitivity than using conventional ultrasound. But the overall sensitivity obtained has not reached levels that allow omitting the randomized systematic biopsy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Detection of prostate cancer by an FDG-PET cancer screening program: results from a Japanese nationwide survey

Objective(s): The aim of this study was to analyze detection rates and effectiveness of 18F-fluorodeoxyglucose positron emission tomography (FDG-PET) cancer screening program for prostate cancer in Japan, which is defined as a cancer-screening program for subjects without known cancer. It contains FDG-PET aimed at detection of cancer at an early stage with or without additional screening tests ...

متن کامل

A review on the role of oral ginseng on erection dysfunction and fatigue in prostate cancer patients

Background: Current pharmacological and non-pharmacological   treatment strategies   for   prostate cancer may control disease progression and increase the survival rates of patients but decreased quality of life is the most important concern of existing medical interventions. Erection dysfunction and fatigue are the most prevalent adverse effects of therapeutic procedures which impair the qual...

متن کامل

Non – Detection of HPV DNA in Prostatic Cancer and Benign Prostatic Hyperplasia: a case- control study in Kerman

Background: Different studies assessed the role of inflammation in malignancy of different organs. Prostatitis has been suggested as a cause of cancer and BPH. Till now, more than 100 types of human Papilloma virus (HPV) are recognized including low and high-risk groups for carcinogenesis. Among them HPV-16 and HPV-18 have shown further association with cancer. Regarding the pr...

متن کامل

Elastography of the prostate in the detection of prostate cancer

Introduction This paper presents initial experience with a new Toshiba elastography imaging system used to detect prostate cancer. Since this is a preliminary evaluation, the elastography imaging procedure was performed in addition to our standard procedure of ten systematic biopsies, plus extra biopsies of suspicious areas where appropriate. The elastography images did not influence the biopsy...

متن کامل

Impact of Real-Time Elastography versus Systematic Prostate Biopsy Method on Cancer Detection Rate in Men with a Serum Prostate-Specific Antigen between 2.5 and 10 ng/mL

The actual gold standard for the diagnosis of prostate cancer includes the serum prostate-specific antigen, the digital rectal examination, and the ultrasound-guided systematic prostate biopsy sampling. In the last years, the real-time elastography has been introduced as an imaging technique to increase the detection rate of prostate cancer and simultaneously reduce the number of biopsies sampl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014