On the origin of increased sensitivity and mass resolution using silicon masks in MALDI.
نویسندگان
چکیده
Since its development, MALDI has proved its performance in the analysis of intact biomolecules up to high molecular weights, regardless of their polarity. Sensitivity of MALDI instruments is a key point for breaking the limits of observing biomolecules of lower abundances. Instrumentation is one way to improve sensitivity by increasing ion transmission and using more sensitive detection systems. On the other side, improving MALDI ion production yields would have important outcomes. MALDI ion production is still not well-controlled and, indeed, the amount of ions produced per laser shot with respect to the total volume of desorbed material is very low. This has particular implications for certain applications, such as MALDI MS imaging where laser beam focusing as fine as possible (5-10 μm) is searched in order to reach higher spatial resolution images. However, various studies point out an intrinsic decrease in signal intensity for strong focusing. We have therefore been interested in developing silicon mask systems to decrease an irradiated area by cutting rather than focusing the laser beam and to study the parameters affecting sensitivity using such systems. For this, we systematically examined variation with laser fluence of intensity and spectral resolution in MALDI of standard peptides when using silicon-etched masks of various aperture sizes. These studies demonstrate a simultaneous increase in spectral resolution and signal intensity. Origin of this effect is discussed in the frame of the two-step ionization model. Experimental data in the low fluence range are fitted with an increase of the primary ionization through matrix-silicon edge contact provided by the masks. On the other hand, behavior at higher fluence could be explained by an effect on the secondary ionization via changes in the plume dynamics.
منابع مشابه
The Effect of Corrugations on Mechanical Sensitivity of Diaphragm for MEMS Capacitive Microphone
In this paper the effect of corrugated diaphragm on performance of MEMS microphone is described. The corrugated diaphragm is modeled in order to improve the sensitivity of micromachined silicon acoustic sensor. Analytical analyzes have been carried out to derive mathematic expressions for the mechanical sensitivity and displacement of corrugated diaphragm with residual stress. It is shown that ...
متن کاملComparing MALDI-ToFMass Spectrometry with Molecular and Biochemical Methods in Identifying Enterococcus Faecium and Enterococcus FaecalisIsolated from Clinical Samples
Abstract Background and Objective: Enterococci are Gram-positive members of human gastrointestinal flora,in Dairy products and environment. they have emerged as important causes of opportunistic nosocomial infections in recent years. In this study we aimed to investigat and compare the efficiency of MALDI-TOFmass spectroscopy method through Biochemical and Molecular methods for detecting Enter...
متن کاملMonte Carlo-based optimization of a gamma probe system for sentinel lymph node mapping
Introduction: Sentinel lymph node biopsy (SLNB) is a standard surgical technique to identify sentinel lymph node (SLN) for the staging of early breast cancer. Nowadays, two methods are used for the identification of SLN: blue dye method aiding visually and radioactive dye using gamma detector. A wide range of gamma probe systems with different design and performance are used in...
متن کاملاندازهگیری نمای فراوانی فسفر کشت شده فراسطحی در سیلیسیوم
We have initiated a study to extract concentration profiles of ultra shallow phosphorous implants in silicon complementing published work on ultra shallow boron implant profiles. There is an ever-increasing interest in the production of p-n junctions in silicon to create the new generations of ultra large scale integrated (ULSI) devices. Such junctions can be formed by implantation do pants (...
متن کاملارزیابی کولیماتورهای لایهای در تصویربرداری تابش ترمزی حین رادیو دارو درمانی با فسفر-32
Background and purpose: Imaging which is used in nuclear medicine is done using emit gamma rays whereas therapy in nuclear medicine is performed by applying radionuclide’s which emit beta radiation. Using Bremsstrahlung is a new field which is recently introduced in imaging. In the Bremsstrahlung imaging, collimator design should not be based on energy peak and whole energy spectrum should be c...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Analytical chemistry
دوره 86 3 شماره
صفحات -