Assessment of malignancy in pulmonary lesions: FDG dual-head coincidence gamma camera imaging in association with serum tumor marker measurement.

نویسندگان

  • V Bousson
  • J L Moretti
  • P Weinmann
  • N Safi
  • F Tamgac
  • C Groiselle
  • V de Beco
  • Y Hillali
  • D Valeyre
  • J L Breau
چکیده

UNLABELLED The purpose of the study was to evaluate the performance of dual-head coincidence gamma camera imaging using FDG in association with serum marker assays in identifying lung carcinoma in patients with abnormal findings on chest radiography. METHODS A prospective evaluation of FDG imaging with coincidence detection emission tomography (CDET) using a dual-head gamma camera combined with the assessment of 3 sensitive serum markers of lung cancer (carcinoembryonic antigen, neuron specific enolase, and CYFRA 21-1) was performed on the same day on 58 consecutive patients with known or suspected lung malignancy. RESULTS Fifty-three patients were proven to have lung cancer, and 5 patients had benign lung disease. Coincidence imaging showed significantly increased FDG uptake in 49 of 53 patients with proven malignancy (sensitivity, 92.5%) and in 3 patients with benign disease. FDG imaging had negative findings in 4 patients with proven malignancy and 2 patients with benign disease. Serum tumor marker levels were elevated in 42 of 53 cancer patients (sensitivity, 79.2%) and normal in 11 patients with proven malignancy. Nine patients with proven malignancy had positive findings on FDG images and negative marker assays. Two patients with proven malignancy had negative findings on FDG images and positive marker assays. The positive predictive value for lung cancer was 94.2% for FDG alone and 97.6% for FDG in association with serum markers. CONCLUSION In this study, FDG CDET imaging was a powerful tool for evaluating patients with lung lesions suggestive of malignancy. Although the determination of serum marker levels was less accurate than FDG imaging, positive FDG results found in association with positive markers significantly increased the likelihood of lung malignancy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dual-head gamma camera coincidence imaging in pancreatic cancer.

OBJECTIVE To assess the usefulness of dual-head camera imaging with 2-[fluorine-18]fluoro-2-deoxy-D-glucose (FDG) in the identification of malignant pancreatic lesions. MATERIAL AND METHODS Fifteen (15) patients with pancreatic masses (7 females and 8 males, mean age 52 10 years) have been studied prospectively. After a 12-hour fasting patients received 120 MBq of FDG and were imaged in a dua...

متن کامل

Usefulness of dual-head coincidence gamma camera with thick NaI crystals for nuclear oncology: comparison with dedicated PET camera and conventional gamma camera with thin NaI crystals.

AIM A comparative study of the images obtained with a dual-head coincidence gamma camera with thick NaI crystals (19 mm), a dedicated PET camera with BGO crystals and a conventional gamma camera with thin NaI crystals (9.5 mm) was conducted to clarify the clinical feasibility of a dual-head coincidence gamma camera with thick NaI crystals. METHODS FDG images of 27 patients with malignant tumo...

متن کامل

Mejora En Sensibilidad Con Imagen Tardía De Lesiones Pulmonares Con Fdg-pet

—Purpose. This study was undertaken to determine the value of using dual-time point 18F-fluorodeoxyglucose positron emission tomography (FDG-PET) imaging to distinguish malignant from benign pulmonary lesions after lesion detection by conventional computed tomography chest imaging. Methods. Patients referred for characterization of lung lesions were included in this prospective study. Eighty-th...

متن کامل

Clinical value of dual-phase 18F-FDG SPECT with serum procalcitonin for identification of etiology in tumor patients with fever of unknown origin.

OBJECTIVE The purpose of the study was to evaluate clinical value of dual-phase 18F-FDG SPECT with serum procalcitonin (PCT) in identifying cancers in patients with fever of unknown origin (FUO). METHODS PCT test and dual-phase 18F-FDG SPECT were sequentially performed on 50 consecutive patients with FUO. Two radiologists evaluated all 18F-FDG SPECT data independently. A consensus was reached...

متن کامل

Brain fluorine-18 fluorodeoxyglucose imaging with dual-head coincidence gamma camera: comparison with dedicated ring-detector positron emission tomography.

BACKGROUND AND PURPOSE Dual-head coincidence gamma camera (DHC) imaging has been proposed as an alternative to dedicated ring-detector positron emission tomography (dr-PET) for clinical fluorodeoxyglucose (FDG) studies. The purpose of this investigation was to assess the quality of DHC images in FDG studies of the human brain. METHODS Seven healthy volunteers and 12 patients with various cere...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of nuclear medicine : official publication, Society of Nuclear Medicine

دوره 41 11  شماره 

صفحات  -

تاریخ انتشار 2000