CARDIOVASCULAR MEDICINE Twenty year comparison of a Bjork-Shiley mechanical heart valve with porcine bioprostheses
نویسندگان
چکیده
Objective: To compare survival and outcome in patients receiving a mechanical or bioprosthetic heart valve prosthesis. Design: Randomised prospective trial. Setting: Tertiary cardiac centre. Patients: Between 1975 and 1979, patients were randomised to receive either a Bjork-Shiley or a porcine prostheses. The mitral valve was replaced in 261 patients, the aortic in 211, and both valves in 61 patients. Follow up now averages 20 years. Main outcome measures: Death, reoperation, bleeding, embolism, and endocarditis. Results: After 20 years there was no difference in survival (Bjork-Shiley v porcine prosthesis (mean (SEM)): 25.0 (2.7)% v 22.6 (2.7)%, log rank test p = 0.39). Reoperation for valve failure was undertaken in 91 patients with porcine prostheses and in 22 with Bjork-Shiley prostheses. An analysis combining death and reoperation as end points confirmed that Bjork-Shiley patients had improved survival with the original prosthesis intact (23.5 (2.6)% v 6.7 (1.6)%, log rank test p < 0.0001); this difference became apparent after 8–10 years in patients undergoing mitral valve replacement, and after 12–14 years in those undergoing aortic valve replacement. Major bleeding was more common in Bjork-Shiley patients (40.7 (5.4)% v 27.9 (8.4)% after 20 years, p = 0.008), but there was no significant difference in major embolism or endocarditis. Conclusions: Survival with an intact valve is better among patients with the Bjork-Shiley spherical tilting disc prosthesis than with a porcine prosthesis but there is an attendant increased risk of bleeding.
منابع مشابه
Twelve-year comparison of a Bjork-Shiley mechanical heart valve with porcine bioprostheses.
BACKGROUND Patients undergoing heart-valve replacement may receive a mechanical prosthesis, necessitating lifelong anticoagulant treatment, or a porcine bioprosthesis, which involves no absolute need for anticoagulants. METHODS We carried out a randomized, prospective trial to compare the durability of the Bjork-Shiley mechanical prosthesis (spherical tilting-disk model) and the incidence of ...
متن کاملNon-invasive assessment by Doppler ultrasound of 155 patients with bioprosthetic valves: a comparison of the Wessex porcine, low profile Ionescu-Shiley, and Hancock pericardial bioprostheses.
One hundred and fifty five patients with 167 bioprosthetic valves (68 Wessex porcine, 54 Hancock pericardial, and 45 low profile Ionescu-Shiley pericardial valves) were studied by Doppler ultrasound. Valve gradients were calculated from the mitral and aortic flow velocities by the modified Bernoulli equation. Mean mitral gradients were significantly smaller across the Ionescu-Shiley valves than...
متن کاملThirteen year-experience with mitral valve replacement.
At the Niigata University Hospital, various kinds of prosthetic valves such as the Starr-Edwards nonclothand cloth-covered, Bjork-Shiley tilting disc, and Carpentier-Edwards porcine valves, have been used from September, 1965 to March, 1979 for replacement of diseased valves on 176 patients. The patients with Starr-Edwards nonclothand cloth-covered ball valves showed survival rates of 90 and 84...
متن کاملeComment: Anticoagulation for mechanical heart valves: a current assessment.
Table 1 Reported cases of well functioning mechanical valve without anticoagulation Reference Mean age n Type of Position Mean follow-up Treatment with Peak (years) valve (n) of valve period without anticoagulation gradient anticoagulation (months) across (years) valve thrombotic prophylaxis are from non-randomized case series without controls w2x. Uncomplicated functioning without anticoagulat...
متن کاملHaemolysis with Björk-Shiley and Starr-Edwards prosthetic heart valves: a comparative study.
Slater, S. D., Saflam, I. A., Bain, W. H., Turner, M. A., and Lawrie, T. D. V. (1974). Thorax, 29, 624-632. Haemolysis with Bjork-Shiley and Starr-Edwards prosthetic heart valves: a comparative study. A comparison was made of the haemolytic complications in 85 patients with two different types of Starr-Edwards cloth-covered ball and cage prosthesis with those in 44 patients with the Bjork-Shile...
متن کامل