Accuracy of mode switch algorithms for detection of atrial tachyarrhythmias.

نویسندگان

  • Rod S Passman
  • Kenneth M Weinberg
  • Mark Freher
  • Pable Denes
  • Andi Schaechter
  • Jeffrey J Goldberger
  • Alan H Kadish
چکیده

INTRODUCTION In patients with permanent pacemakers, mode switching events often are interpreted as surrogate markers for atrial tachyarrhythmias. The aim of this study was to determine the accuracy of automatic mode switching algorithms in patients with permanent pacemakers for the diagnosis of atrial tachyarrhythmias. METHODS AND RESULTS Forty patients with tachycardia-bradycardia syndrome and Medtronic Thera or Kappa 700 permanent pacemakers underwent Holter monitoring. Date, time of onset, and duration of each mode switch episode as recorded by the pacemaker and each atrial tachyarrhythmia episode as recorded by the Holter monitor were compared. Sixteen patients had a total of 54 atrial tachyarrhythmias documented on Holter monitoring (47 atrial fibrillation, 7 atrial flutter). Comparison of Holter data with pacemaker interrogation demonstrated that 53 (98.1%) of 54 atrial tachyarrhythmia episodes resulted in mode switching with one 13-second episode of mode switching during sinus rhythm. The sensitivity and specificity of mode switching for the duration of atrial tachyarrhythmias were 98.1% and 100%, respectively. The algorithms detected 98.9% of the total duration of atrial fibrillation and 96.4% of the total duration of atrial flutter. CONCLUSION In patients with tachycardia-bradycardia syndrome and permanent pacemakers having these mode switching algorithms, mode switching events are reliable surrogate markers for atrial tachyarrhythmias. Therefore, mode switching may serve as a valuable tool for clinical decision making and further research into the natural history and burden of atrial tachyarrhythmias.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

New Bayesian discriminator for detection of atrial tachyarrhythmias.

BACKGROUND Accurate, rapid detection of atrial tachyarrhythmias has important implications in the use of implantable devices for treatment of cardiac arrhythmia. Currently available detection algorithms for atrial tachyarrhythmias, which use the single-index method, have limited sensitivity and specificity. METHODS AND RESULTS In this study, we evaluated the performance of a new Bayesian disc...

متن کامل

Prevention of inappropriate therapy in implantable cardioverter-defibrillators: results of a prospective, randomized study of tachyarrhythmia detection algorithms.

OBJECTIVES The purpose of this randomized study was to investigate the performance of single- and dual-chamber tachyarrhythmia detection algorithms. BACKGROUND A proposed benefit of dual-chamber implantable cardioverter-defibrillators (ICDs) is improved specificity of tachyarrhythmia detection. METHODS All ICD candidates received a dual-chamber ICD and were randomized to programmed single- ...

متن کامل

A hemodynamically responsive antitachycardia system. Development and basis for design in humans.

Current automatic implantable cardioverter-defibrillators detect tachyarrhythmias primarily by rate-only algorithms and cannot adequately distinguish hemodynamically stable from unstable tachyarrhythmias. The responses of right atrial (mean) and right ventricular pressures (mean, systolic, diastolic, and pulse) to 64 induced and paced supraventricular and ventricular tachyarrhythmias were studi...

متن کامل

Improvement of the Effective Components in the PDR Positioning Method Based on Detecting the User’s Movement Mode Using Smartphone Sensors

The purpose of this paper is to evaluate and improve the accuracy of indoor positioning using smartphone sensors based on Pedestrian Dead Reckoning (PDR) method. In some specific situations, such as fires or power outages that disable infrastructure-based positioning techniques, using PDR method based on smartphone sensors that perform positioning continuously is a good solution.This paper focu...

متن کامل

Automatic mode switching in atrial fibrillation

Automatic mode switching (AMS) algorithms were designed to prevent tracking of atrial tachyarrhythmias (ATA) or other rapidly occurring signals sensed by atrial channels, thereby reducing the adverse hemodynamic and symptomatic consequences of a rapid ventricular response. The inclusion of an AMS function in most dual chamber pacemaker now provides optimal management of atrial arrhythmias and a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of cardiovascular electrophysiology

دوره 15 7  شماره 

صفحات  -

تاریخ انتشار 2004