Mass spectrometric monitoring of interfacial photoelectron transfer and imaging of active crystalline facets of semiconductors

نویسندگان

  • Hongying Zhong
  • Juan Zhang
  • Xuemei Tang
  • Wenyang Zhang
  • Ruowei Jiang
  • Rui Li
  • Disong Chen
  • Peng Wang
  • Zhiwei Yuan
چکیده

Monitoring of interfacial electron transfer (ET) in situ is important to understand the ET mechanism and designing efficient photocatalysts. We describe herein a mass spectrometric approach to investigate the ultrafast transfer of photoelectrons that are generated by ultraviolet irradiation on surfaces of semiconductor nanoparticles or crystalline facets. The mass spectrometric approach can not only untargetedly detect various intermediates but also monitor their reactivity through associative or dissociative photoelectron capture dissociation, as well as electron detachment dissociation of adsorbed molecules. Proton-coupled electron transfer and proton-uncoupled electron transfer with radical initiated polymerization or hydroxyl radical abstraction have been unambiguously demonstrated with the mass spectrometric approach. Active crystalline facets of titanium dioxide for photocatalytic degradation of juglone and organochlorine dichlorodiphenyltrichloroethane are visualized with mass spectrometry imaging based on ion scanning and spectral reconstruction. This work provides a new technique for studying photo-electric properties of various materials.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Interface Structure of MoO3 on Organic Semiconductors

We have systematically studied interface structure formed by vapor-phase deposition of typical transition metal oxide MoO3 on organic semiconductors. Eight organic hole transport materials have been used in this study. Ultraviolet photoelectron spectroscopy and X-ray photoelectron spectroscopy are used to measure the evolution of the physical, chemical and electronic structure of the interfaces...

متن کامل

Investigation of Mass Transfer Coefficient under Jetting Conditions in a Liquid-Liquid Extraction System

In this research mass transfer coefficient under jetting regime in different directions (from dispersed to continuous and continuous to dispersed phase) has been studied using an experimental setup. n-Butanol-succinic acid-water with low interfacial tension has been selected as experimental chemical system. The effects of various parameters such as jet velocity, nozzle diameter and the heig...

متن کامل

Turbulent Events and Gas-Side Mass Transfer Coefficients in a Wavy Air-Water Stratified Flow

Turbulence structure on the gas side of a wavy stratified flow was experimentally investigated in a near horizontal 18.7 cm (H) 10 cm (W) 5.5m (L) rectangular duct.By applying the Variable Interval Time Averaging (VITA) technique to the hot wire anemometer measurements frequency of occurrence of turbulent events were detected near the air-water interface. Experimental results showed that fr...

متن کامل

Coupling of narrow and wide band-gap semiconductors on uniform films active in bacterial disinfection under low intensity visible light: implications of the interfacial charge transfer (IFCT).

This study reports the design, preparation, testing and surface characterization of uniform films deposited by sputtering Ag and Ta on non-heat resistant polyester to evaluate the Escherichia coli inactivation by TaON, TaN/Ag, Ag and TaON/Ag polyester. Co-sputtering for 120 s Ta and Ag in the presence of N₂ and O₂ led to the faster E. coli inactivation by a TaON/Ag sample within ∼40 min under v...

متن کامل

Mass Transfer Mechanism and Mathematical Model for Extraction Process of L-Theanine across Bulk Liquid Membrane

This paper deals with the extraction of L-Theanine containing Aliquat 336 as a carrier and cyclohexane as solvent across bulk liquid membrane. The optimum operation condition are as follows: extraction time of 150 min, initial concentration of theanine in the feed phase is 1.8 g/L, the carrier concentration is 0.5 M, the ion of the receiving phas...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2017