Current Biomechanical Models of the Index Finger Fail to Predict Experimental Observations

نویسنده

  • Francisco J. Valero-Cuevas
چکیده

Existing computational models of the human fingers are simplistic and do not capture the physics of interactions of the different components of the extensor mechanism. These models, though widely used in the literature to model finger mechanics have not been validated with experimental data. In this paper, we rigorously validate three index finger biomechanical models : the normative model developed by An et al., 1979 and two constant moment arm models presented by An et al. 1983 and Valero-Cuevas et al. 1998, respectively. We compare fingertip forces predicted using these models with forces measured experimentally in a human cadaveric index finger. We observe that while the predictions of all models deviate largely from experimental measurements, fingertip force errors are larger for the extrinsic extensors and the intrinics, tendons that insert into the complex extensor mechanism. We conclude that these errors could be due to inaccuate and incomplete representations of the extensor mechanism in these models. Introduction: The role of the different components of the extensor mechanism in finger function has been long debated in the literature. While several simplistic computational models have been suggested over the years, the normative model developed by An et al. 1979 [1] remains the most comprehensive 3D anatomical model of the index finger to date. Though this model has been employed in several research studies (Eg. [2]), it has never been rigorously validated with experimental data. The model assumes bowstringing of all tendons with joint rotation and a constant force distribution within the different bands of the extensor mechanism, independent of joint posture. Both the above assumptions are modeling simplifications and are contrary to experimental observations. Valero-Cuevas et al. in 1998 [4] emphasized the importance of including changes in force distribution through the extensor mechanism, with finger posture. They modified a constant moment arm model proposed by An et al, 1983 [3], obtained by regression of tendon excursion-joint angle data from cadaveric specimens, to include changes in force distribution through the extensor mechanism with posture. But the validity of fingertip force predictions of neither of these models has been tested with experimental data. In this paper, we rigorously validate the normative model of the index finger as well as the constant moment arm models described in An et al, 1983 and ValeroCuevas et al. 1998, with experimental data collected from a cadaveric index finger in multiple postures. Methods: The seven tendons of the index finger: flexor digitorum profundus (FDP), flexor digitorum superficialis (FDS), extensor indicis (EI), extensor digitorum communis (EDC), first lumbrical (LUM), first dorsal interosseous (FDI), and first palmar interosseous (FPI), in a freshly frozen cadaveric hand were actuated using dc motors controlled by a National Instruments PXI real-time control system (Fig. 1). All possible combinations of ‘low’ (2N) and ‘high’ (10N) tendon tensions were applied to the cadaveric specimen and corresponding fingertip forces and torques were recorded using a 6 DOF load cell attached to the fingertip. This procedure was repeated at four different postures in one cadaveric specimen. A matrix transforming tendon tensions to fingertip forces (which we shall call the action matrix) was regressed from the experimental data in each posture (mean R =0.96). The normative model of the index finger was implemented in MATLAB. The moment arm matrix corresponding to each finger posture was calculated based on rotations of tendon positions as described in [1] and using equations for force distribution through the extensor mechanism described in [5]. The action matrix was calculated by multiplying the inverse transpose of the Jacobian mapping joint angle velocities to Fig.1 Experimental setup used to collect fingertip force data from cadaveric specimens. fingertip velocities, with the moment arm matrix [4]. Similar action matrices were determined for the constant moment arm models of An et al, 1983 and Valero-Cuevas et al., 1998. Fingertip force predictions were obtained by multiplying these action matrices with tendon tensions. All moment arm matrices were scaled to the length of the middle phalanx to reduce the influence of subject variability [1]. Results: The fingertip force vector predicted by each finger model upon application of 1N tension on a single tendon was compared to that generated by the action matrix regressed from experimental data. This was repeated separately for each tendon and for all postures. The magnitude error in Fig 2 is defined as the difference in fingertip force magnitudes for the simulated model and experimental data and the direction error is the angle between the simulated and experimentally observed force vectors. The fingertip force predictions of all models differed largely from experimental measurements for all tendons. Large variations exist even across the different models. The errors for the extrinsic extensors and intrinsics, tendons inserting into the extensor mechanism, were larger than those for the flexors for all models (except the Valero-Cuevas model for FDP). Discussion: Larger errors for finger extensors and intrinsic muscles compared to finger flexors could be attributed to an inaccurate representation of the extensor mechanism in these models. Including deformations of the extensor mechanism with finger posture and the resulting changes in force distribution may lead to more accurate biomechanical finger models [4]. While some of the error could be due to measurement noise and subject-to-subject variability, magnitude errors > 100% and directional errors > 30 degrees are larger than what these sources of error would produce. More detailed and accurate representations of the topology and parameters of the extensor mechanism are necessary to develop reliable biomechanical models of the finger that can then be used to understand motor control of manipulation and changes upon damage. References: [1] KN An, EY Chao, WP lii Cooney, RL Linscheid, Normative model of human hand for biomechanical analysis, Journal of Biomechanics (1979), 12, 775-788 [2] DC Harding, DK Brandt, BM Hillberry, Finger joint force minimization in pianists using optimization techniques, Journal of Biomechanics (1993), 26(12), 1403-1412. [3] KN An, Y Ueba, EY Chao, WP lii Cooney, RL Linscheid, Tendon excursion and moment arm of index finger muscles, Journal of Biomechanics (1983), 16 (6), 419-425. [4] FJ Valero-Cuevas, FE Zajac, CG Burgar, Large indexfingertip forces are produced by subject-independent patterns of muscle excitation. Journal of Biomechanics (1998), 31(8), 693-703, Acknowledgments: This material is based upon work supported by NSF Grants EFRI-COPN 0836042 and NIH Grants AR050520 and AR052345 to FVC. Fig. 2. Box plots showing errors in magnitude and direction of fingertip force vectors predicted by three models of the index finger when 1N tendon tension was applied to the respective tendons. The black circles represent median values.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Conduction Based and Mediator Based Models for Microbial Fuel Cells

Microbial fuel cells (MFCs) are processes used for simultanuous bioenergy capturing and waste treatment. In this study, a model for MFCs based upon a conduction mechanism for electron transfer is proposed, which integrates substrate utilization, current production and conduction and  microbial distribution and growth in batch flow mode. The outputs of the model and that of a mediator based mode...

متن کامل

کاربرد مدل های k-? خطی و غیر خطی در پیش بینی جریان و انتقال حرارت جا به جائی در کانال های با موانع منفصل

Roughness elements or turbulence promoters have been widely used to enhance heat transfer in cooling passages of modern gas turbine blades. Although such ribs substantially enhance heat transfer, the heat transfer coefficient is reduced immediately at corner downstream of each rib, creating hot spots. To remove such hot spots some of the ribs can be detached from the channel walls. In this pape...

متن کامل

Biomechanical Analysis of Force Distribution in Human Finger Extensor Mechanisms

The complexities of the function and structure of human fingers have long been recognised. The in vivo forces in the human finger tendon network during different activities are critical information for clinical diagnosis, surgical treatment, prosthetic finger design, and biomimetic hand development. In this study, we propose a novel method for in vivo force estimation for the finger tendon netw...

متن کامل

Lung Carcinoma Metastasis to the Distal Part of Index Finger: A Case Report

Although acrometastases are rare but clinically they are considered important. Their etiology is quite different from the metastases to other sites; bronchogenic carcinoma is by far the most frequent case. The prognosis is always similar to metastatic bronchial cancer with an average survival of three mo...

متن کامل

A Biomechanical Approach for the Study of Deformation of Red Cells in Narrow Capillaries

This model focuses on the behavior of capillary-tissue fluid exchange system when the diameter of the capillary is less than that of red cell. In vivo and in vitro observations indicate that the width of the gap between the red cell and the vessel wall is generally small compared to the radius of the capillary for a single file flow of red cell in narrow vessel, particularly if the vessel diame...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2011