Nanotoxicology: in Vitro–in Vivo Dosimetry

نویسنده

  • Günter Oberdörster
چکیده

Gangwal et al. (2011) addressed an important topic for nanotoxicology about assessing the toxicity of inhaled nano materials by recom mending relevant concentrations for in vitro toxicity testing. Their efforts to select in vitro concentrations based on reported occupational exposure levels of inhaled nano materials are, indeed, laudable. Their under lying conceptual approach is logical, involving a widely used and well-accepted particle dosimetry model [multiple-path particle dosimetry (MPPD)] to estimate deposited and retained mass doses in the pulmonary alveolar region of nano material-exposed workers. They then expressed these doses as per-unit alveolar surface area in order to select for in vitro testing the same alveolar epithelial cell surface area doses. However, while this concept makes good sense when applying it to short-term (daily) deposited doses, it makes less sense and can be highly misleading when the same approach is used for doses that have accumulated in the alveo lar region after long-term chronic inhalation exposures of humans. Thus, it is unfortunate that the authors made it a main point to estimate (although crudely and with some questionable assumptions) the dose of inhaled nano materials that is retained or accumulated on the pulmonary alveolar surface over a full working lifetime of 45 years of exposure to 1 mg/m 3 airborne concentration. Gangwal et al. then converted this 45-year accumulated surface area dose to an equivalent in vitro concentration (per square centi meter) as a selection criterion for in vitro dosing. Under " Concentrations recommended for in vitro testing, " they concluded that the long-term retained human alveo lar surface area dose equates to in vitro concentrations of 50–68 µg/mL and that These amounts for a full working lifetime lie within the range of the highest in vitro assay concentrations tested in the literature for Ag [silver nano particles] and TiO 2 [titanium dioxide nano-particles] on human, rat, and mouse cell lines. These are extraordinarily high concentrations , and unfortunately this article may be viewed as a justification for using such high in vitro dosing uncritically. Gangwal et al. (2011) did not discuss anywhere in the article the reasoning behind equating lifetime accumulated doses with doses that are given all at once as a bolus in a short-term in vitro system. The difference in dose rate alone— not considering anything else—spans many orders of magnitude. At best, these extrapolated high in vitro concentrations may be labeled as the high-end limit of an …

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Patient absorbed dose comparison in CT and Stereoradiography (EOS) imaging during lower limb torsion evaluation using in-vivo and in-vitro dosimetry methods

Introduction: Accurate evaluation of femoral and tibial torsion is essential for children or adult with legs deformity, becuse incorrect legs morphogenesis can lead to pathological situation. CT scan is commonly used for the measurement of skeletal bone parameters. But, disability in imaging from standing and sitting posture and absorb dose of patients are deficits of this meth...

متن کامل

Skin in vivo Dosimetry in Radiotherapy

Introduction: Due to the prevalence of skin problems in patients after radiotherapy, skin dose measuring is importance. Content: Skin in vivo dosimetry means measuring the patient's (or phantom) skin dose during radiotherapy. According to the ICRP 59, the dose at the depth of 0.07 mm is known as a skin dose. The most radiosensitive epidermis cells are located...

متن کامل

In Vivo Dosimetry Using a Flat Surface Sun Nuclear Corporation Diode in 60co Beams for Some Radiotherapy Treatments in Ghana

Introduction: One of the useful standard quality assurance techniques in radiation therapy is monitoring entrance doses in in-vivo dosimetry. An overall tolerance limit of 5% of the absorbed radiation dose has been recommended by the International Commission of Radiological Units. The implementation of an in vivo dosimet...

متن کامل

Experimental evaluation of midline dose calculation methods in In vivo dosimetry using anatomic thorax phantom

Background: In vivo dosimetry is a method for estimation of overall error in the delivered dose to the patients at the end of radiotherapy process. In this research, two methods for target dose calculation were evaluated on midline and central axis of photon beams in in vivo dosimetry of thorax fields. Materials and Methods: Entrance and exit doses for anterior and lateral fields of thorax were...

متن کامل

Assessment of a 2D EPID-based Dosimetry Algorithm for Pre-treatment and In-vivo Midplane Dose Verification

Introduction: The use of electronic portal imaging devices (EPIDs) is a method for the dosimetric verification of radiotherapy plans both pretreatment and in-vivo. The aim of this study was to test a 2D EPID-based dosimetry algorithm for dose verification of some plans inside a homogenous and anthropomorphic phantom and in-vivo, as well. Materials and Methods: </strong...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 120  شماره 

صفحات  -

تاریخ انتشار 2012