Direct comparison of coronary bare metal vs. drug-eluting stents: same platform, different mechanics?

نویسندگان

  • Wolfram Schmidt
  • Peter Lanzer
  • Peter Behrens
  • Christoph Brandt-Wunderlich
  • Alper Öner
  • Hüseyin Ince
  • Klaus-Peter Schmitz
  • Niels Grabow
چکیده

BACKGROUND Drug-eluting stents (DES) compared to bare metal stents (BMS) have shown superior clinical performance, but are considered less suitable in complex cases. Most studies do not distinguish between DES and BMS with respect to their mechanical performance. The objective was to obtain mechanical parameters for direct comparison of BMS and DES. METHODS In vitro bench tests evaluated crimped stent profiles, crossability in stenosis models, elastic recoil, bending stiffness (crimped and expanded), and scaffolding properties. The study included five pairs of BMS and DES each with the same stent platforms (all n = 5; PRO-Kinetic Energy, Orsiro: BIOTRONIK AG, Bülach, Switzerland; MULTI-LINK 8, XIENCE Xpedition: Abbott Vascular, Temecula, CA; REBEL Monorail, Promus PREMIER, Boston Scientific, Marlborough, MA; Integrity, Resolute Integrity, Medtronic, Minneapolis, MN; Kaname, Ultimaster: Terumo Corporation, Tokyo, Japan). Statistical analysis used pooled variance t tests for pairwise comparison of BMS with DES. RESULTS Crimped profiles in BMS groups ranged from 0.97 ± 0.01 mm (PRO-Kinetic Energy) to 1.13 ± 0.01 mm (Kaname) and in DES groups from 1.02 ± 0.01 mm (Orsiro) to 1.13 ± 0.01 mm (Ultimaster). Crossability was best for low profile stent systems. Elastic recoil ranged from 4.07 ± 0.22% (Orsiro) to 5.87 ± 0.54% (REBEL Monorail) including both BMS and DES. The bending stiffness of crimped and expanded stents showed no systematic differences between BMS and DES neither did the scaffolding. CONCLUSIONS Based on in vitro measurements BMS appear superior to DES in some aspects of mechanical performance, yet the differences are small and not class uniform. The data provide assistance in selecting the optimal system for treatment and assessment of new generations of bioresorbable scaffolds. TRIAL REGISTRATION not applicable.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Scanning electron microscopy analysis of luminal inflammation induced by different types of coronary stent in an animal model.

There is histological evidence that drug-eluting stents are associated with delayed endothelialization and a persistent inflammatory state. Moreover, clusters of inflammatory cells have been observed on luminal surfaces by scanning electron microscopy. With the aim of quantifying this inflammatory response, we implanted one bare-metal stent and two drug-eluting stents containing different doses...

متن کامل

Outcomes following coronary stenting in the era of bare-metal vs the era of drug-eluting stents.

CONTEXT Although drug-eluting stents reduce restenosis rates relative to bare-metal stents, concerns have been raised that drug-eluting stents may also be associated with an increased risk of stent thrombosis. Our study focused on the effect of stent type on population-based interventional outcomes. OBJECTIVE To compare outcomes of Medicare beneficiaries who underwent nonemergent coronary ste...

متن کامل

Characteristics and outcomes of patients with percutaneous coronary intervention for unprotected left main coronary artery disease: a Hong Kong experience.

OBJECTIVE To evaluate the intermediate-term outcomes of patients with unprotected left main coronary artery stenosis who were treated with percutaneous coronary intervention in Hong Kong. DESIGN Historical cohort. SETTING A regional hospital in Hong Kong. PATIENTS Patients with unprotected left main coronary artery disease undergoing stenting with bare-metal stents or drug-eluting stents ...

متن کامل

A comparison of bare-metal and drug-eluting stents for off-label indications.

BACKGROUND Recent reports suggest that off-label use of drug-eluting stents is associated with an increased incidence of adverse events. Whether the use of bare-metal stents would yield different results is unknown. METHODS We analyzed data from 6551 patients in the National Heart, Lung, and Blood Institute Dynamic Registry according to whether they were treated with drug-eluting stents or ba...

متن کامل

Outcomes with various drug eluting or bare metal stents in patients with diabetes mellitus: mixed treatment comparison analysis of 22 844 patient years of follow-up from randomised trials

OBJECTIVES To evaluate the efficacy and safety of currently used drug eluting stents compared with each other and compared with bare metal stents in patients with diabetes. DESIGN Mixed treatment comparison meta-analysis. DATA SOURCES AND STUDY SELECTION PubMed, Embase, and CENTRAL were searched for randomised clinical trials, until April 2012, of four durable polymer drug eluting stents (s...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 23  شماره 

صفحات  -

تاریخ انتشار 2018