Estimation of Measurement Uncertainties for the DGT Passive Sampler Used for Determination of Copper in Water
نویسندگان
چکیده
Diffusion-based passive samplers are increasingly used for water quality monitoring. While the overall method robustness and reproducibility for passive samplers in water are widely reported, there has been a lack of a detailed description of uncertainty sources. In this paper an uncertainty budget for the determination of fully labile Cu in water using a DGT passive sampler is presented. Uncertainty from the estimation of effective cross-sectional diffusion area and the instrumental determination of accumulated mass of analyte are the most significant sources of uncertainty, while uncertainties from contamination and the estimation of diffusion coefficient are negligible. The results presented highlight issues with passive samplers which are important to address if overall method uncertainty is to be reduced and effective strategies to reduce overall method uncertainty are presented.
منابع مشابه
Metal measurement in aquatic environments by passive sampling methods: Lessons learning from an in situ intercomparison exercise.
Passive sampling devices (PS) are widely used for pollutant monitoring in water, but estimation of measurement uncertainties by PS has seldom been undertaken. The aim of this work was to identify key parameters governing PS measurements of metals and their dispersion. We report the results of an in situ intercomparison exercise on diffusive gradient in thin films (DGT) in surface waters. Interl...
متن کاملA novel passive water sampler for in situ sampling of antibiotics.
Passive water sampling has several advantages over active methods; it provides time-integrated data, can save on time and cost compared to active methods, and yield high spatial resolution data through co-deployment of simple, cheap units. However, one problem with many sampler designs in current use is that their uptake rates for trace substances of interest are flow-rate dependent, thereby re...
متن کاملAssessment of trace metals during episodic events using DGT passive sampler: A proposal for water management enhancement
The potential of the Diffusive Gradient Thin-Films (DGT) as a supplemental method for water quality monitoring was employed has been tested through 3 sampling campaigns to measure the trace metals (Cd, Co, Cr, Cu, Pb, Ni and Zn) present in the surface water of a highly urbanized river. Specifically, the study done in the Pasig River (Philippines) seeks to: assess the applicability of DGT passiv...
متن کاملDGT-induced copper flux predicts bioaccumulation and toxicity to bivalves in sediments with varying properties.
Many regulatory frameworks for sediment quality assessment include consideration of contaminant bioavailability. However, the "snap-shots" of metal bioavailability provided by analyses of porewaters or acid-volatile sulfide-simultaneously extractable metal (AVS-SEM) relationships do not always contribute sufficient information. The use of inappropriate or inadequate information for assessing me...
متن کاملMeasurement of free copper(II) ions in water samples with polyvinyl alcohol as a binding phase in diffusive gradients in thin-films.
A technique for the selective measurement of diffusive gradients in thin-films (DGT) for free Cu2+ ions was developed using a 0.030 M solution of polyvinyl alcohol (PVA) as the liquid binding phase with the liquid-type DGT devices (PVA DGT). The PVA DGT had a substantial binding capacity at pH 5.6 - 8.6 and concentrations of competitive Na+ up to 0.7 M. The measurements of PVA DGT and cupric io...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
دوره 2014 شماره
صفحات -
تاریخ انتشار 2014