Continuous monitoring of jugular bulb oxyhaemoglobin saturation using the Edslab dual lumen oximetry catheter during and after cardiac surgery.

نویسندگان

  • S A Millar
  • R P Alston
  • M J Souter
  • P J Andrews
چکیده

Fibreoptic jugular bulb oximetry has been validated for use in the care of severely head-injured patients. We compared bench and fibreoptic methods of measuring jugular bulb oxyhaemoglobin saturation (SjO2) in 33 patients undergoing cardiac surgery both during cardiopulmonary bypass (CPB) and in the early postoperative period. After insertion of a fibreoptic reflectance oximetry catheter into the jugular bulb, it was calibrated against a bench oximeter. Comparisons were made while on CPB (n = 60) and in the postoperative period for up to 18 h (n = 215). There was negligible bias throughout. There were wide limits of agreements (mean difference +/- 2SD) between the two methods during operation (-20.29% to 18.05%), whereas after operation the limits of agreement were far narrower (-6.39% and 7.45%). Measurement of SjO2 by the fibreoptic method compared poorly with bench oximetry during CPB but there was good agreement between the two methods in the early postoperative period.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Should a Double-Lumen Catheter be withdrawn?

Haemodialysis needs a credible and recurrent access to the systemic circulation which can be accomplished by way of central vein catheterization. We report the case of bleeding after withdrawal of the double lumen catheter. A 36-year-old woman who was a known case of end-stage renal disease referred to a dialysis center because of her arteriovenous fistula malfunction. A double-lumen catheter w...

متن کامل

Continuous intra-jugular venous blood-gas monitoring with the Paratrend 7 during hypothermic cardiopulmonary bypass.

We measured the accuracy of the continuous intra-vascular blood-gas monitoring system (Paratrend 7, PT7) placed in the jugular venous bulb in 18 adult patients having cardiac or aortic surgery with hypothermic cardiopulmonary bypass (CPB). After induction of anaesthesia, a PT7 sensor was inserted through a 20-gauge venous catheter into the right jugular venous bulb. Blood samples were drawn fro...

متن کامل

Usefulness of central venous oxygen saturation monitoring during bidirectional Glenn shunt.

A PediaSat™ oximetry catheter (PediaSat: Edwards Lifesciences Co., Ltd., Irvine, CA, U. S. A.), which facilitates continuous measurement of central venous oxygen saturation (ScvO2), may be useful for surgery for pediatric congenital heart disease. We used PediaSat during a bidirectional Glenn shunt. The patient was a 13-month-old boy. Under a diagnosis of left single ventricle (pulmonary atresi...

متن کامل

Jugular bulb hemoglobin oxygen saturation is not a standard for comparison with cerebral oximetry in head injury.

To the Editor:-Minassian et al. I studied the correlation between cerebral cortical oxyhemoglobin saturation and jugular bulb oxyhemoglobin saturation in patients with head injury, and concluded that, ‘‘Sco2 assessed by NIRS does not adequately reflect changes in Svjo, in patients with severe head injury.” However, jugular bulb oximetry may not be an appropriate standard of cerebral oxygenation...

متن کامل

Fiberoptic monitoring of central venous oxygen saturation (PediaSat) in small children undergoing cardiac surgery: continuous is not continuous

BACKGROUND Monitoring of superior vena cava saturation (ScvO 2) has become routine in the management of pediatric patients undergoing cardiac surgery. The objective of our study was to evaluate the correlation between continuous ScvO 2 by the application of a fiber-optic oximetry catheter (PediaSat) and intermittent ScvO 2 by using standard blood gas measurements. These results were compared to...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • British journal of anaesthesia

دوره 82 4  شماره 

صفحات  -

تاریخ انتشار 1999