Influence of sample storage duration on serum protein profiles assessed by surface-enhanced laser desorption/ionisation time-of-flight mass spectrometry (SELDI-TOF MS).
نویسندگان
چکیده
BACKGROUND Issues have been raised concerning the robustness and validity of alleged serum markers discovered by surface-enhanced laser desorption/ionisation time-of-flight mass spectrometry (SELDI-TOF MS). Pre-analytical variables have been shown to exert a profound effect on protein profiles, irrespective of true biological variation. However, little is known about the possible effects of sample storage duration on protein profiles. We, therefore, aimed to investigate the effects of extended storage duration on the serum protein profile. METHODS Archival sera from 140 breast cancer patients, stored at -30 degrees C for 1-11 years, were profiled by SELDI-TOF MS using immobilised metal affinity capture (IMAC) arrays, a condition applied in the majority of breast cancer biomarker discovery studies. RESULTS Fourteen peak clusters, structurally identified as C3a des-arginine anaphylatoxin and multiple fragments of albumin and fibrinogen, were found to be significantly associated with sample storage duration by five distinct patterns. These proteins have been described previously as potential cancer markers, rendering them specific to both disease and sample handling issues. CONCLUSIONS To prevent experimental variation being interpreted erroneously as disease associated variation, assessment of potential confounding pre-analytical parameters is a pre-requisite in biomarker discovery and validation studies. In addition, with respect to the different (non-)linear patterns observed in the current study, simply performing linear corrections to account for sample storage duration will not necessarily suffice.
منابع مشابه
Serum protein profiling for diagnosis of breast cancer using SELDI-TOF MS.
In search for novel markers for breast cancer, we aimed to identify and validate novel serum protein profiles specific for breast cancer, and assess the influence of clinical (subjects age) and pre-analytical (sample storage duration) variables on the constructed classifiers. To this end, sera of breast cancer patients (n=152) and healthy controls (n=129), randomly divided into a training and t...
متن کاملPreanalytic influence of sample handling on SELDI-TOF serum protein profiles.
BACKGROUND High-throughput proteomic methods for disease biomarker discovery in human serum are promising, but concerns exist regarding reproducibility of results and variability introduced by sample handling. This study investigated the influence of different preanalytic handling methods on surface-enhanced laser desorption/ionization time-of-flight mass spectrometry (SELDI-TOF MS) protein pro...
متن کاملSurface-enhanced Laser Desorption/Ionisation Time-of-flight Mass Spectrometry to Detect Breast Cancer Markers in Tears and Serum.
BACKGROUND New biomarkers are needed to improve the early detection of breast cancer. This study describes the use of surface-enhanced laser desorption/ionisation time-of-flight mass spectroscopy (SELDI-TOF-MS) in serum and tear fluid. MATERIALS AND METHODS Blood and tear fluid of 10 women with breast cancer and 10 healthy age-matched women were screened for potential biomarkers. Blood sample...
متن کاملIdentification of serum proteins related to adverse effects induced by docetaxel infusion from protein expression profiles of serum using SELDI ProteinChip system.
BACKGROUND For the development of quick and easy methods for screening and identifying treatment-responsive proteins, we determined the protein expression profile of the serum after docetaxel infusion using a surface-enhanced laser desorption/ionization time-of-flight mass spectroscopy (SELDI TOF-MS) system. MATERIALS AND METHODS Blood from breast cancer patients was collected before and 4, 8...
متن کاملThe Human Urinary Proteome Fingerprint Database UPdb
The use of human urine as a diagnostic tool has many advantages, such as ease of sample acquisition and noninvasiveness. However, the discovery of novel biomarkers, as well as biomarker patterns, in urine is hindered mainly by a lack of comparable datasets. To fill this gap, we assembled a new urinary fingerprint database. Here, we report the establishment of a human urinary proteomic fingerpri...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry and laboratory medicine
دوره 47 6 شماره
صفحات -
تاریخ انتشار 2009