Accuracy of chest radiography for positioning of the umbilical venous catheter.

نویسندگان

  • Adriana F M Guimarães
  • Aline A C G de Souza
  • Maria Cândida F Bouzada
  • Zilda M A Meira
چکیده

OBJECTIVES To evaluate the accuracy of the simultaneous analysis of three radiographic anatomical landmarks - diaphragm, cardiac silhouette, and vertebral bodies - in determining the position of the umbilical venous catheter distal end using echocardiography as a reference standard. METHODS This was a cross-sectional, observational study, with the prospective inclusion of data from all neonates born in a public reference hospital, between April 2012 and September 2013, submitted to umbilical venous catheter insertion as part of their medical care. The position of the catheter distal end, determined by the simultaneous analysis of three radiographic anatomical landmarks, was compared with the anatomical position obtained by echocardiography; sensitivity, specificity, positive predictive value, negative predictive value, and accuracy were calculated. RESULTS Of the 162 newborns assessed by echocardiography, only 44 (27.16%) had the catheter in optimal position, in the thoracic portion of the inferior vena cava or at the junction of the inferior vena cava with the right atrium. The catheters were located in the left atrium and interatrial septum in 54 (33.33%) newborns, in the right atrium in 26 (16.05%), intra-hepatic in 37 (22.84%), and intra-aortic in-one newborn (0.62%). The sensitivity, specificity and accuracy of the radiography to detect the catheter in the target area were 56%, 71%, and 67.28%, respectively. CONCLUSION Anteroposterior radiography of the chest alone is not able to safely define the umbilical venous catheter position. Echocardiography allows direct visualization of the catheter tip in relation to vascular structures and, whenever possible, should be considered to identify the location of the umbilical venous catheter.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Location of the Central Venous Catheter Tip With Bedside Ultrasound in Young Children: Can We Eliminate the Need for Chest Radiography?

OBJECTIVE To compare the use of bedside ultrasound and chest radiography to verify central venous catheter tip positioning. DESIGN Prospective observational study. SETTING PICU of a university hospital. PATIENTS Patients aged 0-14 who required a central venous catheter. INTERVENTION None. MEASUREMENTS AND MAIN RESULTS Central venous catheter tip location was confirmed by ultrasound an...

متن کامل

Pleural and Pericardiac Effusion as a Complication of Properly Placed Umbilical Venous Catheter

Pleural and pericardial effusions are extremely rare complications of umbilical venous catheterization in newborns. A preterm male infant weighing 850g, with insertion of an umbilical venous catheter (UVC) developed massive right pleural and pericardial effusions. The position of catheter tip was verified by chest radiography and echocardiography. The effusions were drained by thoracentesis and...

متن کامل

Semi-Automated Location Identification of Catheters in Digital Chest Radiographs

Localization of catheter tips is the most common task in intensive care unit imaging. In this work, catheters appearing in digital chest radiographs acquired by portable chest x-rays were tracked using a semi-automatic method. Due to the fact that catheters are synthetic objects, its profile does not vary drastically over its length. Therefore, we use forward looking registration with normalize...

متن کامل

Neonatal atrial flutter after insertion of an intracardiac umbilical venous catheter

OBJECTIVE To describe a case of neonatal atrial flutter after the insertion of an intracardiac umbilical venous catheter, reporting the clinical presentation and reviewing the literature on this subject. CASE DESCRIPTION A late-preterm newborn, born at 35 weeks of gestational age to a diabetic mother and large for gestational age, with respiratory distress and rule-out sepsis, required an umb...

متن کامل

Agitated Saline Bubble−Enhanced Ultrasound for Assessing Appropriate Position of Hemodialysis Central Venous Catheter in Critically Ill Patients

APACHE, Acute Physiology and Chronic Health Evaluation; ICU, intensive care unit; SOFA, Sequential Organ Failure Assessment. To the Editor: Renal replacement therapy is recommended to be initiated immediately in patients with life-threatening acute kidney injury (AKI) related symptoms. Ultrasound-guided insertion of hemodialysis catheter is recommended for vascular access. Agitated saline bubbl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Jornal de pediatria

دوره 93 2  شماره 

صفحات  -

تاریخ انتشار 2017