Biocompatibility and Pharmacokinetic Analysis of an Intracameral Polycaprolactone Drug Delivery Implant for Glaucoma

نویسندگان

  • Jean Kim
  • Max Kudisch
  • Sri Mudumba
  • Hiroyuki Asada
  • Eri Aya-Shibuya
  • Robert B. Bhisitkul
  • Tejal A. Desai
چکیده

PURPOSE We developed polycaprolactone (PCL) implants that achieve zero-order release of a proprietary ocular hypotensive agent (DE-117) over 6 months. METHODS The release rates of DE-117-loaded PCL devices were tuned based on an established predictive model and confirmed by in vitro release studies. Devices containing DE-117 and empty devices were implanted intracamerally in normotensive rabbits for up to 8 weeks' duration. Devices were retrieved after rabbits were euthanized and evaluated for tissue adherence. The drug remaining in each device was analyzed by high performance liquid chromatography. Drug distribution in ocular tissues was measured by liquid chromatography coupled with a tandem mass spectrometry (LC/MS/MS). RESULTS In vitro release of DE-117 showed zero-order release with a release rate of 0.5 μg/day over 6 months. Implantation in rabbit eyes demonstrated that the devices were well tolerated in the intracameral space. Quantification of DE-117 and hDE-117 (the hydrolyzed active form of DE-117) in ocular tissues (cornea, iris-ciliary body, aqueous humor, and vitreous humor) indicated sustained release of DE-117 and its conversion to hDE-117 when released from the device. Analysis of drug remaining in the device found that concentration of hDE-117 was below the limit of detection, indicating the encapsulated drug was protected from hydrolysis in the device. CONCLUSIONS Proof-of-concept PCL drug delivery devices containing DE-117 show promise as a long-term glaucoma treatment based on their zero-order drug release profile in vitro, biocompatibility in vivo, and effective distribution of released drug in relevant ocular tissues.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Environmental friendly carrier material for nifedipine as hypertension drug

Nifedipine is a hypertension drug must be consumed three times a day due to its low oral bioavailability. One way of developing a controlled drug delivery system is making nifedipine microcapsules by using environmentally friendly polymers of polylactic acid and polycaprolactone via the evaporation method using oil-in-water solvents. Polylactic acid and polycaprolactone can be said to be enviro...

متن کامل

Evaluation of in vitro and in vivo biocompatibility of a myo-inositol hexakisphosphate gelated polyaniline hydrogel in a rat model.

Recent advances in understanding the interaction between electricity and cells/biomolecules have generated great interest in developing biocompatible electrically conductive materials. In this study, we investigated the biocompatibility of a myo-inositol hexakisphosphate gelated polyaniline hydrogel using in vitro and in vivo experiments in a rat model. The polyaniline hydrogel was used to coat...

متن کامل

Biological Application of Layered Double Hydroxides in Drug Delivery Systems

This review focuses on the extensive study of different layered double hydroxides (LDHs)nanostructures and also their biological and physicochemical (in vitro) properties to encapsulateand deliver drugs with a recognized pharmacokinetic profile in a sustained/modified manner forbetter remedial efficacy contrasted to the corresponding conventional treatments using different<br ...

متن کامل

Intracameral air injection during Ahmed glaucoma valve implantation in neovascular glaucoma for the prevention of tube obstruction with blood clot

RATIONALE Glaucoma drainage implant surgery is a treatment option for the management of neovascular glaucoma. However, tube obstruction by blood clot after Ahmed glaucoma valve (AGV) implantation is an unpredictable clinically challenging situation. PATIENT CONCERNS-DIAGNOSES-INTERVENTIONS We report 4 cases using intracameral air injection for the prevention of the tube obstruction of AGV by ...

متن کامل

The Effect of Silica Coating on the Drug Release Profile and Biocompatibility of Nano-MOF-5

The purpose of this study was the surface modification of nano MOF-5 (NMOF-5) or IRMOF-1 (Zn4O(C8H4O4)3) in order to prevent its rapid degradation in the phosphate-buffered saline (PBS), along with the simultaneous increase in its biocompatibility. The NMOF-5 sample was synthesized under the ultrasound irradiation and then it was loaded wit...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 57  شماره 

صفحات  -

تاریخ انتشار 2016