Use of a 24 Gauge Intravenous Cannula for Minimally Invasive Trabeculectomy

نویسندگان

  • Tanuj Dada
  • Dewang Angmo
  • Shreyas Temkar
  • Reetika Sharma
چکیده

We describe an innovative technique for performing standardized low cost glaucoma filtration surgery using a polytetrafluoroethylene (PTFE) intravenous cannula. The trocar of a 24 gauge (24G) PTFE intravenous cannula was used to create a trabeculectomy ostium and its tube was inserted under a partial thickness scleral flap in 2 patients with advanced glaucomatous optic neuropathy, in whom intraocular pressure (IOP) was not controlled on maximal tolerable hypotensive therapy. Postoperatively, IOP of the operated eyes at 3, 6 and 9 months' follow-up ranged from 12 to 15 mmHg with a well formed anterior chamber and a diffuse bleb.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Routine Offered Protocol is not reliable for Thrombophlebitis Prevention

Background: Intravenous catheterization is a routine technique in medical centers which can cause diverse problems such as thrombophlebitis. Objective: This study aimed to resolve replacement scheduling and proper cannula diameter and position issues for intravenous catheters. Methods: In this 2015 experimental cohort study, 232 hos...

متن کامل

Minimally Invasive Surgical Approach to Distal Fibula Fractures: A Technique Tip

  Wound complications following ankle fracture surgery are a major concern. Through the use of minimally invasive surgical techniques some of these complications can be mitigated. Recent investigations have reported on percutaneous fixation of distal fibula fractures demonstrating similar radiographic and functional outcomes to traditional open approaches. The purpose of this manuscript is to ...

متن کامل

Evaluation of 3-mm diameter intravenous tubing for the rapid infusion of fluids.

The use of intravenous administration systems incorporating 3-mm internal diameter tubing is becoming more common in hospital practice. The maximum flow-rate of crystalloid solutions through 3-mm-diameter tubing is compared to that through conventional 4-mm tubing when connected to standard large-gauge intravenous cannulae. Lengths of intravenous tubing between 80 cm and 200 cm were tested in c...

متن کامل

Aspiration of breast abscess through wide bore 14-gauge intravenous cannula.

OBJECTIVE To aspirate breast abscess through a wide bore (14-gauge) intravenous (I/V) cannula and determine its efficacy in terms of the number of recurrences and number of aspirations. STUDY DESIGN Case series. PLACE AND DURATION OF STUDY Dow University of Health Sciences and Civil Hospital and Bantva Hospital, Karachi, Pakistan, from January 2009 to December 2011. METHODOLOGY Patients w...

متن کامل

Outcomes of 23-Gauge Vitrectomy Combined with Phacoemulsification, Panretinal Photocoagulation, and Trabeculectomy without Use of Anti-VEGF Agents for Neovascular Glaucoma with Vitreous Hemorrhage

Purpose. To evaluate the outcomes of 23-gauge vitrectomy combined with phacoemulsification, PRP and trabeculectomy without use of anti-VEGF-agents for NVG. Methods. Eighteen eyes of 18 patients with NVG underwent 23-gauge vitrectomy combined with phacoemulsification, PRP and trabeculectomy without use of anti-VEGF agents. The preoperative BCVA ranged from light perception to 0.2. The preoperati...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2015