Coil-by-Coil vs. Direct Virtual Coil (DVC) Parallel Imaging Reconstruction: An Image Quality Comparison for Contrast- Enhanced Liver Imaging

نویسندگان

  • P. J. Beatty
  • J. H. Holmes
  • S. Chang
  • E. Bayram
  • J. H. Brittain
  • S. B. Reeder
چکیده

P. J. Beatty, J. H. Holmes, S. Chang, E. Bayram, J. H. Brittain, and S. B. Reeder Applied Science Laboratory, GE Healthcare, Menlo Park, CA, United States, Applied Science Laboratory, GE Healthcare, Waukesha, WI, United States, GE Healthcare, Waukesha, WI, United States, Applied Science Laboratory, GE Healthcare, Madison, WI, United States, Departments of Radiology and Medical Physics, University of Wisconsin-Madison, Madison, WI, United States

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Clinical performance of contrast enhanced abdominal pediatric MRI with fast combined parallel imaging compressed sensing reconstruction.

PURPOSE To deploy clinically, a combined parallel imaging compressed sensing method with coil compression that achieves a rapid image reconstruction, and assess its clinical performance in contrast-enhanced abdominal pediatric MRI. MATERIALS AND METHODS With Institutional Review Board approval and informed patient consent/assent, 29 consecutive pediatric patients were recruited. Dynamic contr...

متن کامل

Non-uniformity of Clinical Head, Head and Neck, and Body Coils in Magnetic Resonance Imaging (MRI)

Introduction Signal intensity uniformity in a magnetic resonance (MR) image indicates how well the MR imaging (MRI) system represents an object. One of the major sources of image non-uniformity in high-field MRI scanners is inhomogeneity of radio-frequency coil. The aim of this study was to investigate non-uniformity in head, head and neck, and body coils and compare the obtained results to det...

متن کامل

Automatic Coil Selection for SENSE Imaging with Large Coil Arrays

Introduction Parallel imaging using coil arrays with large number of receive elements allows improved imaging performance and increased SNR [1, 2]. However, the use of a large number of coil elements can lead to memory storage problems and to increased reconstruction times. Several techniques for data reduction were presented, realized either by linear combination of the original coil data or b...

متن کامل

Assessment of the Characteristics of MRI Coils in Terms of RF Non-Homogeneity Using Routine Spin Echo Sequences

Introduction: One of the major causes of image non-uniformity in MRI is due to the existence of  non-homogeneity in RF receive and transmit. This can be the most effective source of error in  quantitative  studies  in  MRI  imaging.  Part  of  this  non-homogeneity  demonstrates  the  characteristics of RF coil and part of it is due to the interaction of RF field with the material being  imaged...

متن کامل

Estimating Absolute-Phase Maps Using ESPIRiT and Virtual Conjugate Coils

PURPOSE To develop an ESPIRiT-based method to estimate coil sensitivities with image phase as a building block for efficient and robust image reconstruction with phase constraints. THEORY AND METHODS ESPIRiT is a new framework for calibration of the coil sensitivities and reconstruction in parallel magnetic resonance imaging. Applying ESPIRiT to a combined set of physical and virtual conjugat...