Uniformity testing: assessment of a centralized web-based uniformity analysis system.

نویسنده

  • Meaghan C Klempa
چکیده

UNLABELLED Uniformity testing is performed daily to ensure adequate camera performance before clinical use. The aim of this study is to assess the reliability of Beth Israel Deaconess Medical Center's locally built, centralized, Web-based uniformity analysis system by examining the differences between manufacturer and Web-based National Electrical Manufacturers Association integral uniformity calculations measured in the useful field of view (FOV) and the central FOV. METHODS Manufacturer and Web-based integral uniformity calculations measured in the useful FOV and the central FOV were recorded over a 30-d period for 4 cameras from 3 different manufacturers. These data were then statistically analyzed. The differences between the uniformity calculations were computed, in addition to the means and the SDs of these differences for each head of each camera. RESULTS There was a correlation between the manufacturer and Web-based integral uniformity calculations in the useful FOV and the central FOV over the 30-d period. The average differences between the manufacturer and Web-based useful FOV calculations ranged from -0.30 to 0.099, with SD ranging from 0.092 to 0.32. For the central FOV calculations, the average differences ranged from -0.163 to 0.055, with SD ranging from 0.074 to 0.24. CONCLUSION Most of the uniformity calculations computed by this centralized Web-based uniformity analysis system are comparable to the manufacturers' calculations, suggesting that this system is reasonably reliable and effective. This finding is important because centralized Web-based uniformity analysis systems are advantageous in that they test camera performance in the same manner regardless of the manufacturer.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Non-uniformity of Clinical Head, Head and Neck, and Body Coils in Magnetic Resonance Imaging (MRI)

Introduction Signal intensity uniformity in a magnetic resonance (MR) image indicates how well the MR imaging (MRI) system represents an object. One of the major sources of image non-uniformity in high-field MRI scanners is inhomogeneity of radio-frequency coil. The aim of this study was to investigate non-uniformity in head, head and neck, and body coils and compare the obtained results to det...

متن کامل

Investigating the Influence of Filter Uniformity Coefficient and Effective Pore Size on Critical Hydraulic Gradient and Maximum Erosion of Dispersive and Non-dispersive Samples

Filter is one of the main components of embankment dams. By a simple but effective performance, filter protects the dam against erosion and soil scouring in impervious core caused by leakage (piping) and makes it safe. Interaction between filter and erodible base soil is a complex phenomenon which is dependent upon several factors, and has challenged researchers for better understanding the fil...

متن کامل

Microsatellite Markers to Complement Distinctness, Uniformity, Stability Testing of Brassica chinensis (Xiao Baicai) Varieties

Brassica chinensis varieties are mostly consumed as vegetables. In order to assess utility of microsatellite markers for testing distinctness, uniformity and stability of B. chinensis varieties, we used nine polymorphic microsatellite marker loci (with a total of 131 alleles) to evaluate four open pollinated and four hybrid varieties of B. chinensis. Each variety was represented by 48 randomly ...

متن کامل

Assessment of the Characteristics of MRI Coils in Terms of RF Non-Homogeneity Using Routine Spin Echo Sequences

Introduction: One of the major causes of image non-uniformity in MRI is due to the existence of  non-homogeneity in RF receive and transmit. This can be the most effective source of error in  quantitative  studies  in  MRI  imaging.  Part  of  this  non-homogeneity  demonstrates  the  characteristics of RF coil and part of it is due to the interaction of RF field with the material being  imaged...

متن کامل

Restriction to uniformity and political accountability

This paper discusses the fundamental hypothesis of policy uniformity under centralized decision making underlying Oates’ famous decentralization theorem. The theorem has come under pressure by the prediction that local public goods are provided to minimum winning coalitions rather than uniformly. The focus of this paper is on the impact of uniformity rules on political accountability. Using the...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of nuclear medicine technology

دوره 39 2  شماره 

صفحات  -

تاریخ انتشار 2011