INTRODUCTION Locked plates are commonly used to obtain fixation in periarticular and comminuted fractures. Their use has also gained popularity in repairing fractures in osteoporotic bone. These plates provide stable fixation and promote biological healing. Over the last 3 years, we have used over 150 locked plates with varying success to fix periarticular fractures involving mainly the knee and ankle. In this study, we report our clinical experience and the difficulties encountered when removing locked plates in adult patients with a variety of indications including implant failure, infection, non-union and a palpable symptomatic implant. METHODS A retrospective analysis was performed of patients enrolled prospectively into a database. Included in the study were 36 consecutive adult patients who each underwent the procedure of locked plate removal in a single inner city level 1 trauma centre. Data collected included primary indication for fixation, indication for implant removal, time of the implant in situ, grade of operating surgeon and difficulties encountered during the procedure. RESULTS Implant removal was associated with a complication rate of 47%. The major problems encountered were difficulty in removing the locked screws and the implant itself. A total of ten cold welded screws were found in eight cases. Removal was facilitated by high speed metal cutting burrs and screw removal sets in all but one case, where a decision was made to leave the plate in situ. CONCLUSIONS The majority of studies investigating implant removal and problems encountered in doing so report a relatively high complication rate. With the advent of locking plates and their growing popularity, difficulties are now being seen intraoperatively when removing them. There is a paucity of data, however, specifically directed at locking plate removal. We recommend that surgeons should be aware of the potential complications while removing locked plates. Fluoroscopic control and all available extra equipment (mainly metal cutting burrs and screw removal sets) should be available in theatre.
منابع مشابه
Removal of locking plates: new implant, new challenges and new solutions
Removal of locking plates in many ways poses novel challenges compared to conventional plates. None of the techniques described for the removal of locking plates are adequate for all situations. We report our experience of 27 patients from whom a total of 33 locking plates were removed. We also describe a novel technique for the removal of locking plates which in our experience could be used in...
متن کاملA comparison of plates with and without locking screws in a calcaneal fracture model.
BACKGROUND We compared different plates in an experimental calcaneal fracture model under biocompatible loading. METHODS Four plates were tested: a plate without locked screws (Synthes), and three different plates with locked screws (Newdeal, Darco, Synthes). Synthetic calcanei (Sawbone) were osteotomized to create a fracture model, and the plates were fixed onto them. Seven specimens for eac...
متن کاملComparison of dynamic and locked compression plates for treating midshaft clavicle fractures.
The purpose of this study was to compare the parameters of perioperative course and cost-effectiveness for patients with midshaft clavicle fractures treated by dynamic compression plates or locked compression plates.This retrospective, case-controlled study involved 54 patients with midshaft clavicle fractures who received dynamic compression plates (n=21) or locked compression plates (n=33) be...
متن کاملBiomechanics of locked plates and screws.
OBJECTIVE To review the biomechanical principles that guide fracture fixation with plates and screws; specifically to compare and contrast the function and roles of conventional unlocked plates to locked plates in fracture fixation. We review basic plate and screw function, discuss the design rationale for the new implants, and examine the biomechanical evidence that supports the use of such im...
متن کاملPolyaxially-locked plate screws increase stability of fracture fixation in an experimental model of calcaneal fracture.
Different calcaneal plates with locked screws were compared in an experimental model of a calcaneal fracture. Four plate models were tested, three with uniaxially-locked screws (Synthes, Newdeal, Darco), and one with polyaxially-locked screws (90 degrees +/- 15 degrees ) (Rimbus). Synthetic calcanei were osteotomised to create a fracture model and then fixed with the plates and screws. Seven sp...
متن کامل