Blood loss from laboratory tests.

نویسندگان

  • Dirk Wisser
  • Klaus van Ackern
  • Ernst Knoll
  • Hermann Wisser
  • Thomas Bertsch
چکیده

BACKGROUND Laboratory tests can be an important source of blood loss in hospitals, especially for newborns and patients in intensive care. The aim of this study was to quantify blood loss for laboratory diagnostic tests in a large number of patients in a teaching hospital. METHODS We estimated blood loss by multiplying the number and volumes of sampling tubes collected from 2654 adult inpatients. We compared the number of tests per patient for all inpatients and intensive care unit patients during the first period and again in the same time period 1 year later when cumulative blood-loss volumes were being reported to physicians and educational information had been given to decrease blood loss from laboratory tests. RESULTS For 95% of the patients, blood loss during hospitalization was <196 mL. The largest proportion of the blood samples was used for clinical chemical tests (median, 45%), followed by hematologic (median, 26%) and coagulation (median, 17%) tests. In the surgical and cardiovascular surgical intensive care units, however, blood gas analyses accounted for 19-34% (medians) of the use. For 5% of the patients, all undergoing intensive care, blood loss was >200 mL and for 0.7% was >600 mL during their hospital stay. Such high blood losses were observed in patients with long-term ventilation, coagulation disorders, and repeated surgery. The largest median blood loss was in patients undergoing cardiovascular surgery (median, 201 mL). The mean number of tests was 44 per inpatient before cumulative blood loss was being reported and 46 when it was being reported. CONCLUSIONS Blood loss from laboratory diagnostic testing is not likely to pose a problem for most hospitalized patients. Blood loss is greater in intensive care patients and after cardiovascular surgical procedures. Reporting of the cumulative individual blood loss did not decrease blood loss for laboratory testing.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of structured use of routine laboratory tests or near-patient assessment with clinical judgement in the management of bleeding after cardiac surgery.

BACKGROUND Using algorithms based on point of care coagulation tests can decrease blood loss and blood component transfusion after cardiac surgery. We wished to test the hypothesis that a management algorithm based on near-patient tests would reduce blood loss and blood component use after routine coronary artery surgery with cardiopulmonary bypass when compared with an algorithm based on routi...

متن کامل

Management of massive operative blood loss.

Coagulopathy associated with massive operative blood loss is an intricate, multicellular and multifactorial event. Massive bleeding can either be anticipated (during major surgery with high risk of bleeding) or unexpected. Management requires preoperative risk evaluation and preoperative optimization (discontinuation or modification of anticoagulant drugs, prophylactic coagulation therapy). Int...

متن کامل

Transmission of hepatitis C by blood splash into conjunctiva in a nurse.

The risk of transmission of hepatitis C virus (HCV) infection is an important problem for the health care worker. HCV transmission by blood splashing into eyes is very rare. In a hemodialyses department, a 23-year-old female nurse splashed blood from a patient who was anti-HCV positive into her eyes. She washed her eyes with water immediately and reported to the infection control department. Sh...

متن کامل

A Case Report of Blood Group Discrepancy because of Anti A1 with Clinical Significance and Anti C

Abstract Background and objectives: ABO phenotyping is one of the essential tests in Immunohematology. Incompatible blood group transfusion leads to acute hemolysis reactions and other serious complications. Anti A1 is a cold Antibody with no clinical significance, but if it is reacted at 37˚c can be clinically significant, which will be happened rarely. At the present, we report a Case with a...

متن کامل

Performance Comparison of Two Different Branded Blood Collection Tubes Used in Biochemistry Laboratory

Background and Aims: Blood collection tubes (BCT) with gel separators are diagnostic devices that can affect all laboratory processes. In this study, the aim was to compare the performance of a new brand of BCT with the sample tubes that are well-known and widely used in the market. Materials and Methods: Blood samples were taken from 50 healthy volunteers to two brands of BCTs (KWS and BD Vac...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 49 10  شماره 

صفحات  -

تاریخ انتشار 2003