Cerebral aneurysm perforations complicating therapy with Guglielmi detachable coils: a meta-analysis.
نویسندگان
چکیده
BACKGROUND AND PURPOSE The risk of intraprocedural aneurysm perforation in patients with previously ruptured aneurysms tends to be higher than that of patients with previously unruptured aneurysms, but a statistically significant difference has not been shown. Our purpose was to define the rates of occurrence and of morbidity and mortality associated with aneurysmal perforation associated with coil embolization. METHODS A meta-analysis of the results from 17 published retrospective reports of aneurysm perforations complicating therapy with Guglielmi detachable coils (GDCs) was performed. Rates of perforation and associated morbidity and mortality in previously ruptured and unruptured aneurysms were calculated. The mechanism of perforation was noted. RESULTS The risk of intraprocedural perforation was significantly higher in patients with ruptured aneurysms compared with patients with unruptured aneurysms (4.1% vs 0.5%; P <.001). The combined risk of permanent neurologic disability and death associated with intraprocedural aneurysm perforation was 38% for ruptured aneurysms and 29% for unruptured aneurysms. The morbidity and mortality rates with perforations caused by coils (39%) and microcatheters (33%) were similar. The morbidity and mortality rate for microguidewire perforations was considerably lower (0%, n = 4) than the rates for coils and microcatheters, but number of cases was too low to indicate statistical significance. CONCLUSION The risk of aneurysm perforation during GDC therapy is much higher in patients with previously ruptured aneurysms than in those with unruptured aneurysms. The morbidity and mortality rates are substantial for perforations caused by coils and microcatheters, whereas they seem to be much lower for perforations caused by microguidewires.
منابع مشابه
Topic review: surface modifications enhancing biological activity of guglielmi detachable coils in treating intracranial aneurysms.
BACKGROUND Endovascular therapy with Guglielmi detachable coils is an accepted treatment option for patients with intracranial aneurysms. However, an emerging technology in the realm of endovascular tools is the use of traditional Guglielmi detachable coils with biologically active substances complexed to the coil surface to enhance aneurysm occlusion. METHODS We review the literature and cur...
متن کاملUse of three-dimensional Guglielmi detachable coils in the treatment of wide-necked cerebral aneurysms.
A three-dimensional Guglielmi detachable coil (3D-GDC) has been developed that is designed specifically to bridge the neck of an aneurysm with coil loops, thereby facilitating retention of additional coils placed within the aneurysm. Nine wide-necked cerebral aneurysms were successfully embolized using the 3D-GDC, provided that the dome-to-neck ratio was 1.5 or greater.
متن کاملEndovascular treatment of ruptured, peripheral cerebral aneurysms: parent artery occlusion with short Guglielmi detachable coils.
We report two cases of distal cerebral aneurysms that were treated by parent artery occlusion with short Guglielmi detachable coils (GDCs). One patient had a presumed mycotic aneurysm of the distal left posterior cerebral artery, and the other had a partially clipped aneurysm of the distal right anterior inferior cerebellar artery that had hemorrhaged. Short GDCs allow controlled, accurate occl...
متن کاملBasilar tip aneurysm: endovascular treatment with Guglielmi detachable coils--midterm results.
PURPOSE To determine the safety and effectiveness of Guglielmi detachable coils in the endovascular treatment of ruptured and nonruptured basilar tip aneurysms. MATERIALS AND METHODS A basilar tip aneurysm was occluded with Guglielmi detachable coils in 21 patients. The aneurysmal diameter was small (less than 12 mm) in 15 patients, large (12-25 mm) in four patients, and giant (more than 25 m...
متن کاملMR angiography with ultrashort echo time in cerebral aneurysms treated with Guglielmi detachable coils.
We evaluated a time-of-flight three-dimensional MR angiographic sequence with an ultrashort echo time for its ability to characterize the perfusional state of cerebral aneurysms that had been treated with Guglielmi detachable coils and to depict adjacent cerebral arteries. The results were compared with findings at conventional MR angiography and digital subtraction angiography. Adjacent vessel...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- AJNR. American journal of neuroradiology
دوره 23 10 شماره
صفحات -
تاریخ انتشار 2002