Improvement of multislice oxygen-enhanced MRI of the lung by fully automatic non-rigid image registration.

نویسندگان

  • Francesco Molinari
  • Grzegorz Bauman
  • Guglielmo Paolantonio
  • Tobias Geisler
  • Bernhard Geiger
  • Lorenzo Bonomo
  • Hans-Ulrich Kauczor
  • Michael Puderbach
چکیده

PURPOSE In oxygen-enhanced magnetic resonance imaging of the lung (O2-MRI), motion artifacts related to breathing hamper the quality of the parametric O2-maps. In this study, fully automatic non-rigid image registration was assessed as a post-processing method to improve the quality of O2-MRI. MATERIALS AND METHODS Twenty healthy volunteers were investigated on a 1.5 T MR system. O2-MRI was obtained in four coronal sections using an IR-HASTE sequence with TE/TI of 12/1200 ms. Each section was repeatedly imaged during oxygen and room-air ventilation. Spatial differences among the images were corrected by fully automatic non-rigid registration. Signal variability, relative enhancement ratio between oxygen and room air images, and spatial heterogeneity of lung enhancement were assessed before and after image registration. RESULTS Motion artifacts were corrected in 5-10s. Non-rigid registration reduced signal variability of the source images and heterogeneity of the O2-maps by 1.1 ± 0.2% and 11.2 ± 2.9%, respectively (p<0.0001). Registration did not influence O2 relative enhancement ratio (p=0.06). CONCLUSION Fully automatic non-rigid image registration improves the quality of multislice oxygen-enhanced MRI of the lung.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

بهبود سرعت &quot;انطباق مبتنی بر روش برش گراف&quot; جهت انطباق غیر صلب تصاویر تشدید مغناطیسی مغز

Image processing methods, which can visualize objects inside the human body, are of special interests. In clinical diagnosis using medical images, integration of useful data from separate images is often desired. The images have to be geometrically aligned for better observation. The procedure of mapping points from the reference image to corresponding points in the floating image is called Ima...

متن کامل

New Pseudo-CT Generation Approach from Magnetic Resonance Imaging using a Local Texture Descriptor

Background: One of the challenges of PET/MRI combined systems is to derive an attenuation map to correct the PET image. For that, the pseudo-CT image could be used to correct the attenuation. Until now, most existing scientific researches construct this pseudo-CT image using the registration techniques. However, these techniques suffer from the local minima of the non-rigid deformation energy f...

متن کامل

Towards automatic image registration of hyperpolarized He MRI and x-ray CT images of the lung

Introduction Initial work on He MRI to CT image registration [1] demonstrated the feasibility of fusing the images using control point rigid registration. More recently, an enhanced acquisition and registration protocol has been reported [2] that utilizes a new radiofrequency (RF) body coil, a 3D volume He MR acquisition sequence, and a multislice radiotherapy CT scanner. Although He MRI to CT ...

متن کامل

Free-Breath DCE MRI for Solitary Pulmonary Nodule with Motion Correction Based on Non-Rigid Image Registration

Introduction Dynamic contrast-enhanced (DCE) MRI has proven valuable to characterize tissue of interest in solitary pulmonary nodule (SPN) [1], especially for delineating malignant from benign tumor. In DCE MRI studies, the kinetics of signal variation at lesions following the administration of the contrast agent is analyzed from time-intensity curve. Thus, it is crucial to measure the signal i...

متن کامل

Comparison and evaluation of rigid and non-rigid registration of breast MR images

In this paper we present a new approach for the non-rigid registration of contrast-enhanced breast MRI. A hierarchical transformation model of the motion of the breast has been developed: The global motion of the breast is modelled by an a ne transformation while the local breast motion is described by a free-form deformation (FFD) based on B-splines. Normalised mutual information is used as a ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European journal of radiology

دوره 81 10  شماره 

صفحات  -

تاریخ انتشار 2012