Determination of perfluorinated compounds in packaging materials and textiles using pressurized liquid extraction with gas chromatography-mass spectrometry.

نویسندگان

  • Gang Lv
  • Libing Wang
  • Shaocong Liu
  • Shufen Li
چکیده

A simultaneous determination method of trace amounts of perfluorinated compounds, such as perfluorooctanoic acid (PFOA) and perfluorooctane sulfonate (PFOS) in packaging materials and textiles, has been developed, using pressurized liquid extraction (PLE) with gas chromatography-mass spectrometry (GC/MS). The perfluorinated compounds were primarily extracted from the samples by a PLE procedure, in which the parameters were optimized by response surface methodology. The solvent was then removed by blowing nitrogen and a silylation step was carried out with N,N-bis(trimethylsilyl)trifluoroacetamide. The silylated compounds were identified and quantified by GC/MS. The proposed method was applied to determine the PFOA and PFOS in polytetrafluoroethylene packaging materials and textiles, where the detection limits of the two compounds were 1.6 and 13.9 ng mL(-1), respectively. The results showed that the concentrations of PFOA and PFOS in the packaging materials and textiles ranged from 17.5 to 45.9 and 33.7 to 81.3 ng g(-1), respectively.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simultaneous Determination of 13 Priority Polycyclic Aromatic Hydrocarbons in Tehran’s Tap Water and Water for Injection Samples Using Dispersive Liquid-Liquid Micro Extraction Method and Gas Chromatography-Mass Spectrometry

Abstract Polycyclic aromatic hydrocarbons (PAHs) are classified as persistent and carcinogenic organic pollutants. PAHs contamination has been reported in water. Many of relevant regulatory bodies such as EU and EPA have regulated the limit levels for PAHs in drinking water. In this study, 13 priority polycyclic aromatic hydrocarbons (PAHs) were determined in tap water samples of Tehran and wat...

متن کامل

Simultaneous Determination of 13 Priority Polycyclic Aromatic Hydrocarbons in Tehran’s Tap Water and Water for Injection Samples Using Dispersive Liquid-Liquid Micro Extraction Method and Gas Chromatography-Mass Spectrometry

Abstract Polycyclic aromatic hydrocarbons (PAHs) are classified as persistent and carcinogenic organic pollutants. PAHs contamination has been reported in water. Many of relevant regulatory bodies such as EU and EPA have regulated the limit levels for PAHs in drinking water. In this study, 13 priority polycyclic aromatic hydrocarbons (PAHs) were determined in tap water samples of Tehran and wat...

متن کامل

Detection and Determination of some Migrated Chemicals from Plastic Containers into Different Drinks and Liquids Using Dispersive Liquid-liquid Microextraction Prior to Gas Chromatography

Migration of chemicals from plastic containers into drinks and liquids containing them, is supposed to be a hazardous phenomenon and results in many health problems. Sample preparation is of great importance due to trace amounts analysis of these compounds. In this research, dispersive liquid–liquid microextraction is applied for the extraction and preconcentration of the migrated compounds pri...

متن کامل

Determination of Organic Sulfur Contaminants Using Hollow Fibre-protected Liquid-phase Micro-extraction Coupled with Gas Chromatography

A simple and solvent-minimized sample preparation technique based on hollow fibre-protected liquid-phase micro-extraction has been developed for extraction of fifteen organic sulphur compounds from aqueous samples. The analysis of the extracted them was performed by gas chromatography equipped with mass spectrometry and/or flame photometric detectors. 3.3 µL of organic solvent located in the lu...

متن کامل

Simultaneous Analysis of Metabolite Residues from Degradation of Dithiocarbamates in Cereals Using Liquid Chromatography Coupled with Tandem Mass Spectrometry

Background and Objectives: Dithiocarbamates are groups of fungicides used to control pests of agricultural products. Analysis of these pesticides with liquid and gas chromatography instruments is associated with various problems due to the presence of metal groups in the structure of these compounds. Therefore, one of the ways for analysis the pesticides is to check the level of decomposition...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical sciences : the international journal of the Japan Society for Analytical Chemistry

دوره 25 3  شماره 

صفحات  -

تاریخ انتشار 2009