Measurement of acetabular inclination and anteversion via CT generated 3D pelvic model
نویسندگان
چکیده
BACKGROUND Inclination and anteversion were the main factors that determined the reliability of the acetabulum. Inclination and anteversion measurements included anatomical, operational and radiographic methods. The aim of our present study was to exhibit divergence of inclination and anteversion via the three measurements. METHODS Inclination and anteversion were defined according to the definitions put forward by Murray. Three-dimensional models of pelvis of CT data were brought forth. Acetabular axis was determined by the rim of acetabula. Reference planes were established by bone landmarks including anterior superior iliac spine, pubic tubercles and sacral crests. Inclinations and anteversions were calculated according to the definitions. RESULTS Forty-nine cases were involved in the research. Data of inclination form anatomical, operational and radiographic showed 37.48 ± 11.07, 45.12 ± 14.76 and 48.76 ± 14.36, and anteversion were 18.12 ± 7.59, 24.97 ± 9.68, 14.30 ± 5.64. A substantial deviation was noted in the inclinations (P < 0.01) and anteversions (P < 0.01). CONCLUSION Our findings suggested that the inclinations and anteversions of the three measurements varied, which might in turn interfere the decision of orthopedists.
منابع مشابه
Measuring Acetabular Cup Orientation on Antero-Posterior Radiographs of the Hip after Total Hip Arthroplasty with a Vector Arithmetic Radiological Method. Is It Valid and Verified for Daily Clinical Practice?
PURPOSE The aim of this prospective study is to validate a vector arithmetic method for measuring acetabular cup orientation after total hip arthroplasty (THA) and to verify the clinical practice. MATERIALS AND METHODS We measured cup anteversion and inclination of 123 patients after cementless primary THA twice by two examiners on AP pelvic radiographs with a vector arithmetic method and com...
متن کاملCorrecting for Pelvic Posture Influence on Cup Anteversion Measurements
INTRODUCTION Malposition of the acetabular component is a risk factor for postoperative dislocation after total hip arthroplasty (THA)[1]. Current radiographic techniques for assessing cup anteversion have been developed, but they have limitations[2]. The purpose of this study is to investigate the effect of and reduce the error caused by various pelvis postures on cup anteversion measurement. ...
متن کاملComputed tomography assessment of image-free navigation-assisted cup placement in THA in an Asian population.
The authors hypothesized that an image-free navigation system would be more accurate than postoperative 3-dimensional (3-D) reconstructed computed tomography (CT) for acetabular cup inclination and anteversion during total hip arthroplasty (THA) in an Asian population. Eighty-one THAs were performed in 72 patients using the OrthoPilot image-free navigation system (B. Braun Aesculap, Tuttlingen,...
متن کاملThree-dimensional acetabular orientation measurement in a reliable coordinate system among one hundred Chinese
Determining three-dimensional (3D) acetabular orientation is important for several orthopaedic scenarios, but the complex geometries of both pelvis and acetabulum make measurements of orientation unreliable. Acetabular orientation may also differ between the sexes or racial groups. We aimed to (1) establish and evaluate a novel method for measuring 3D acetabular orientation, (2) apply this new ...
متن کاملAccuracy of acetabular cup positioning using imageless navigation
BACKGROUND Correct placement of the acetabular cup is a crucial step in total hip replacement to achieve a satisfactory result and remains a challenge with free-hand techniques. Imageless navigation may provide a viable alternative to free-hand technique and improve placement significantly. The purpose of this project was to assess and validate intra-operative placement values for both inclinat...
متن کامل