A Review on Finite Element Analysis of Beam to Column Endplate Bolted Connection

نویسندگان

  • Kuldeep Kaushik
  • Avadesh K. Sharma
  • Rishi Kumar
چکیده

This paper gives a bibliographical review of the methods which are applied for the analysis of Beam to column bolted end plate connection from the theoretical as well as practical points of view. The bibliography at the end of the paper contains 84 references of papers and conference proceedings on the subject that were published between 1914 and 2011. These are classified in the following categories:  Conventional methods like experimental, empirical, analytical, mechanical, informational and other methods.  Finite Element Method(s) (FEM) using different software like ANSYS, ABACUS etc.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Analytical and Experimental Investigation of I Beam-to-CFT Column Connections under Monotonic Loading (RESEARCH NOTE)

In this study, the behavior characteristics of I beam-to-concrete filled tube (CFT) column connection is studied through experiment and finite element models under the monotonic loading. To validate the finite element modeling, at first, an experimental model is made and experimented. After validation of the finite element modeling, different models were created in the software. The studied par...

متن کامل

Numerical Analysis of Cyclic Behavior of Beam-To-Column Bolted Connections in Steel Frames

This article considers the seismic behavior of beam-to-column joints in steel frames for different bolt arrangements by using of finite element modeling. As the most important beam-to-column joint type, the beam-to-column joints with end-plate is chosen for the analysis. Four different specimens have been analyzed. These models had some differences such as bolt arrangement and the presence or a...

متن کامل

Finite element analysis of a rigid beam to column connection reinforced with channels

Abstract: This research work presents a new rigid connection constructed with channels. In order to assess its hysteresis behavior, three specimens with different cover plates and six specimens with different panel zone thickness have been considered. The energy absorbed by the connection and the behavior of the panel zone were studied during cyclic loading and compared with those of connectio...

متن کامل

A Study on the Ductility of Bolted Beam - Column Connections

The behaviour of beam-column joint plays an important role in the response of a steel moment resisting framed structure especially under seismic excitation. Semi rigid connections like bolted joints, allow better energy dissipation and provide good response under lateral loads. In this paper the ductility and energy dissipation characteristics of semi rigid bolted connections using double web a...

متن کامل

Numerical Analysis of End Plate Bolted Connection with Corrugated Beam

Steel extended end plate bolted connections are recommended to be widely utilized in special moment-resisting frame subjected to monotonic loading. Improper design of steel beam to column connection can lead to the collapse and fatality of structures. Therefore comprehensive research studies of beam to column connection design should be carried out. Also the performance and effect of corrugated...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013