Comparability and reproducibility of apex cardiogram recorded with six different transducer systems.
نویسندگان
چکیده
A comparison was made in 7 dogs of the results obtained by 6 different apex cardiographic transducers applied before, during, and after controlled infusion of angiotensin and isoprenaline. The electrocardiogram, internal phonocardiogram, aortic and left ventricular pressure using a Telco micromanometer, and apex cardiogram were recorded simultaneously on magnetic tape and paper. Digital computer techniques were used to derive various measurements. The comparison of the 6 transducer systems was made expecially with respect to measurements derived from the normalised derivative, calculated using total as well as developed pressure or displacement. Measurements derived from left ventricular pressure were very reproducible. Differences in results of 'contractility' indices varied between 0.5 and 1.9 per cent. Indices from the apex cardiogram using 6 different transducer systems showed variations up to 20 per cent, with mean values varying between 3.2 and 8.1 per cent. There was a systematic deviation for one transducer system, which was responsible for a significant part of the observed variability. It may be concluded that in order to assure maximal reproducibility, technical characteristics of the apex cardiograph transducer should be taken into account and an optimal recording technique should be used.
منابع مشابه
Time relation between apex cardiogram and left ventricular events using simultaneous high-fidelity tracings in man.
In 10 patients without left heart valvular disease and having normal function of the left ventricle, the left ventricular apex cardiogram with its first derivative (dA/dt), left ventricular pressure with its first derivative (dP/dt), aortic pressure, electrocardiogram, and phonocardiogram were reocrded simultaneously during cardiac catheterization. The apex cardiographic tracings were obtained ...
متن کاملTransmission of audible praecordial gallop sounds to right supraclavicular fossa.
To evaluate the significance of audible gallop sounds in the right supraclavicular fossa we performed simultaneous external heart sound recordings at 50 and 100 Hz at the left ventricular apex, left sternal border, and right supraclavicular fossa in 50 patients with audible gallop sounds at the left ventricular apex. In each patient heart sounds were recorded with a simultaneous jugular phlebog...
متن کاملRelation between apex cardiogram and changes in left ventricular pressure and dimension.
The relation between the apex cardiogram and changes in left ventricular pressure measured by micromanometer, and dimension measured by echocardiography, was studied in 12 normal subjects and 64 patients with heart disease. In 12 patients, the apex cardiogram was delayed with respect to simultaneous left ventricular pressure by 17 +/- 18 ms during the upstroke and 28 +/- 16 ms during the downst...
متن کاملThe Normal Apex Cardiogram Its Temporal
T HE apex cardiogram was described in 1878 by Marey.' With the exception of its utilization in the timing of the opening snap of the mitral valve 2 3 and in the identification of the third and fourth heart sounds,4-6 it has been used only infrequently as an aid in timing cardiac phenomena. Technical difficulties in its recording have obstructed its more universal application and, more particula...
متن کاملThe Normal Apex Cardiogram
T HE apex cardiogram was described in 1878 by Marey.' With the exception of its utilization in the timing of the opening snap of the mitral valve 2 3 and in the identification of the third and fourth heart sounds,4-6 it has been used only infrequently as an aid in timing cardiac phenomena. Technical difficulties in its recording have obstructed its more universal application and, more particula...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- British heart journal
دوره 41 6 شماره
صفحات -
تاریخ انتشار 1979