Simulation Result about Harmonics Filtering for Improving the Functioning Regime of the UHP EAF

نویسندگان

  • MANUELA PANOIU
  • CAIUS PANOIU
  • MIHAELA OSACI
  • IONEL MUSCALAGIU
چکیده

This paper present the results obtained by simulation for the functioning regime improvement of an UHP Electric Arc Furnace. Because the nonlinearity of the electric arc the EAF functioning regime are perturbed from three causes: the current harmonics, the reactive power and the unbalanced load. In this paper there are study the possibilities of harmonics filtering and compensate the reactive power. The study was made using the results of some measurements made on an EAF and using an electric arc model for simulation. The simulations are performed in PSCAD EMTDC simulation program, a program dedicated to the power system. Key-Words: PSCAD-EMTDC simulation program, electric arc modeling, harmonics mitigation, filtering, reactive power compensation

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Power filtering method with controllable inductance for eliminating thyristor rectifier load harmonics

In this paper, we propose a Controlled Inductance Power Filter (CIPF) to solve power quality problems in industrial DC power supply systems. This method is based on the theory of magnetic potential equilibrium combined with active hybrid filter technology. Initially the system structure and filter wiring scheme are presented and the equivalent circuit is performed with the mathematical models o...

متن کامل

A Comparison between SVC and STATCOM in Flicker Mitigation of Electric Arc Furnace using Practical Recorded Data

Electric arc furnace (EAF) is one of the largest loads in electric power systems. It is highly time varying and nonlinear. Its reactive power variations cause voltage fluctuations in nearby system which is known as flicker. On the other hand the nonlinear voltage-current characteristic causes strong voltage and current harmonics in EAF. To this end Flexible AC Transmission Systems (FACTS) techn...

متن کامل

A Coordinated Control Scheme for Improving Voltage Quality Using Power Electronics Interfaced DGs

Recently, increasing of non-linear loads in the power distribution network has been increased harmonics in these networks. The harmonics problems get worse and complicated by installation of power factor correction capacitors and filters. But the Distributed Generations (DGs) interface inverters with properly control can help to improve power quality, harmonic compensation and voltage unbalance...

متن کامل

Control of Inverter-Interfaced Distributed Generation Units for Voltage and Current Harmonics Compensation in Grid-Connected Microgrids

In this paper, a new approach is proposed for voltage and current harmonics compensation in grid-connected microgrids (MGs). If sensitive loads are connected to the point of common coupling (PCC), compensation is carried out in order to reduce PCC voltage harmonics. In absence of sensitive loads at PCC, current harmonics compensation scenario is selected in order to avoid excessive injection of...

متن کامل

ارتقای کیفیت توان و بهبود فرآیند کنترل کوره قوس الکتریکی با استفاده از UPQC

Electrical Arc Furnace (EAF) is large, nonlinear and time-varying load that affects power quality of the power system by producing many problems such as harmonics, flicker, current unbalance and low power factor. This paper proposes a modified Unified Power Quality Conditioner (UPQC) to reduce power quality problems of EAF and enhance its controllability. Harmonic reduction, power quality impro...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2007