Keratoconic Bi - aspheric Contact Lenses
نویسنده
چکیده
Aim: This observational clinical case series examined patients with keratoconus (KC) fit with keratoconic bi-aspheric (KBA) lenses to assess visual acuity (VA), wavefront aberrations, physiological fitting, subjective comfort, and manufacturer’s fitting guidelines. Materials and methods: Seven adult patients (11 eyes, four females, mean age: 34.15 ± 14.12) with nipple cones from the Hadassah Academic College contact lens clinic (Jerusalem, Israel) were fit with KBA lenses by modifying the initial base curve (BC) to obtain an acceptable physiological fit. The uncorrected and corrected distance (D) and near (N) Snellen VA and the ocular wavefront measurements, and responses to a self-administered five-point scale questionnaire were compared after 2 weeks of wear using paired two-tailed t-test or MannWhitney U test, as appropriate. Results: Visual acuity and total root mean square (RMS) improved signif icantly with the lenses (DVAuncorrected = 0.04 ± 0.02, DVAcorrected = 0.66 ± 0.22, NVAuncorrected = 0.34 ± 0.30, NVAcorrected = 0.95 ± 0.12). Subjects reported an average of 7.0 ± 2.7 hours of wear daily, with good scores in visual stability, satisfaction with VA and quality of vision, improvement of mood and quality of life, and low scores in foreign body sensation, pain, red eye, and itching during wear, and difficulty with lens removal. An average of two BC modifications from the diagnostic lens were necessary (0.16 mm steeper in nine eyes, 0.27 mm flatter in two eyes). Conclusion: Keratoconic bi-aspheric lenses can provide 7 hours of comfortable wear, significantly improved VA and total RMS aberrations, alongside subjective satisfaction. Base curve modifications can be reduced by fitting a diagnostic lens 0.75 mm steeper than the flattest keratometry reading.
منابع مشابه
Profile Measurement of Micro-aspheric Surface by a Small-scale Measuring Instrument
INTRODUCTION Along with the miniaturization of optical devices such as medical endoscopes and fiber-optic communication systems, micro-aspheric lenses (1 mm in diameter) have become very important parts [1]. Micro-aspheric lenses are necessary for downsizing and higher image quality. Form accuracy of micro-aspheric lenses is required to be better than 100 nm to make the most of those devises. H...
متن کاملCorrecting anterior corneal aberration and variability of lens movements in keratoconic eyes with back-surface customized soft contact lenses.
Customized contact lenses are limited in their correction performance, especially on irregular corneas, owing to decentration and rotation of the lenses. To overcome this limitation, we proposed to customize the back surface of soft contact lenses to match the anterior irregular corneal surface. These lenses were designed to correct anterior corneal aberrations and to improve lens stability. Al...
متن کاملThe Lower- and Higher-Order Aberrations of the Eye
Keratoconus causes a reduction in the optical quality of the eye as a result of corneal distortion, corneal scarring and higher-order aberrations. The correction of these optical aberrations would significantly improve the visual performance of keratoconic eyes. However the first step would be to measure the optical flaws in keratoconus accurately, which in itself presents a challenge. This pap...
متن کاملVision improvement by correcting higher-order aberrations with customized soft contact lenses in keratoconic eyes.
Higher-order aberration correction in abnormal eyes can result in significant vision improvement, especially in eyes with abnormal corneas. Customized optics such as phase plates and customized contact lenses are one of the most practical, nonsurgical ways to correct these ocular higher-order aberrations. We demonstrate the feasibility of correcting higher-order aberrations and improving visual...
متن کاملOn-eye performance of custom wavefront-guided soft contact lenses in a habitual soft lens-wearing keratoconic patient.
PURPOSE To assess visual, optical, and fitting characteristics for wavefront-guided soft contact lenses produced for one habitual soft lens-wearing moderate keratoconic eye. METHODS A process for production and evaluation of custom wavefront-guided soft contact lenses was developed. Wavefront aberrations were quantified with the COAS-HD wavefront sensor (Wavefront Sciences); soft contact lens...
متن کامل