Experimental results from an Imarad 8]8 pixellated CZT detector

نویسندگان

  • W. Li
  • Z. He
  • G. F. Knoll
  • D. K. Wehe
  • J. E. Berry
چکیده

This paper reports experimental results obtained from an 8]8 pixellated CZT detector provided by Imarad Imaging Systems. Three arbitrarily selected pixels were independently tested using c rays of di!erent energies. The signals from an anode pixel and the cathode were read out simultaneously. From the observations of the pulse waveforms from both the anode pixel and the cathode, the electron-injection e!ect leading to electron}hole combination was not observed. The best energy resolution at 122 keV from the three pixels was 7.8, 6.6 and 9.4 keV, respectively, while resolution at 662 keV was 29.3, 11.8 and 26.5 keV, respectively. The electronic noise from the three pixels was similar (5 keV), so the variation in the best energy resolution indicates material nonuniformity in the detector. For the material underneath the three selected pixels, the mobility-lifetime product for electrons was measured to be 3.4, 2.4 and 1.8 (]10~3 cm2/V), respectively, and the resistivity was measured to be 8, 10 and 8.3 (]109 ) cm), respectively. The variation in these results also shows the material nonuniformity across the detector. In the test with 662 keV c rays, the pulse-height ratio of the signals from the cathode and pixel can be used to infer the interaction depth of single-pixel events. Results and analyses are presented in this paper. ( 2001 Elsevier Science B.V. All rights reserved.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Development of Gold Contacted Flip-chip Detectors with IMARAD CZT

We present initial results from our evaluation of a gold-contacted pixellated detector using cadmium zinc telluride substrate produced by IMARAD Imaging Systems. The Horizontal Bridgman (HB) grown crystals from IMARAD have been shown to produce high resolution photopeaks, but they are also seen to have large leakage current. Our previous tests with IMARAD CZT showed that the use of indium anode...

متن کامل

ar X iv : a st ro - p h / 05 08 62 3 v 1 2 9 A ug 2 00 5 Direct comparison of the performance of CZT detectors contacted with various metals

Cadmium Zinc Telluride (CZT) achieves excellent spatial resolution and good energy resolution over the broad energy range from several keV into the MeV energy range. In this paper we present the results of a systematic study of the performance of CZT detectors manufacturered by Orbotech (before IMARAD) depending on surface preparation, contact materials and contact deposition. The standard Orbo...

متن کامل

Thick CZT Detectors for Space-Borne X-ray Astronomy

Cadmium Zinc Telluride (CZT) detectors are having a major impact on the field of hard X-ray astronomy. Without the need for cryogenic cooling they achieve good spatial and energy resolutions over the broad energy range from 10 keV to ∼600 keV. In this paper, we briefly review the historical development of detectors used in Xray astronomy. Subsequently, we present an evaluation of CZT detectors ...

متن کامل

Design and Testing of a Prototype Pixellated CZT Detector and Shield for Hard X-Ray Astronomy

We report on the design and laboratory testing of a prototype imaging CZT detector intended for balloon flight testing in April 2000. The detector tests several key techniques needed for the construction of large-area CZT arrays, as required for proposed hard X-ray astronomy missions. Two 10 mm × 10 mm × 5 mm CZT detectors, each with a 4 × 4 array of 1.9 mm pixels on a 2.5 mm pitch, will be mou...

متن کامل

Balloon Flight Background Measurement with Actively-Shielded Planar and Imaging CZT Detectors

We present results from the flight of two prototype CZT detectors on a scientific balloon payload in September 2000. The first detector, referred to as “CZT1,” consisted of a 10 mm × 10 mm × 2 mm CZT crystal with a single gold planar electrode readout. This detector was shielded by a combination of a passive collimator in the front, giving a 40 degree field of view and surrounded by plastic sci...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2001