Vasodilation increases pulse pressure variation, mimicking hypovolemic status in rabbits
نویسندگان
چکیده
OBJECTIVE To test the hypothesis that pulse pressure respiratory variation (PPV) amplification, observed in hypovolemia, can also be observed during sodium nitroprusside (SNP)-induced vasodilation. INTRODUCTION PPV is largely used for early identification of cardiac responsiveness, especially when hypovolemia is suspected. PPV results from respiratory variation in transpulmonary blood flow and reflects the left ventricular preload variations during respiratory cycles. Any factor that decreases left ventricular preload can be associated with PPV amplification, as seen in hypovolemia. METHODS Ten anesthetized and mechanically ventilated rabbits underwent progressive hypotension by either controlled hemorrhage (Group 1) or intravenous SNP infusion (Group 2). Animals in Group 1 (n = 5) had graded hemorrhage induced at 10% steps until 50% of the total volume was bled. Mean arterial pressure (MAP) steps were registered and assumed as pressure targets to be reached in Group 2. Group 2 (n = 5) was subjected to a progressive SNP infusion to reach similar pressure targets as those defined in Group 1. Heart rate (HR), systolic pressure variation (SPV) and PPV were measured at each MAP step, and the values were compared between the groups. RESULTS SPV and PPV were similar between the experimental models in all steps (p > 0.16). SPV increased earlier in Group 2. CONCLUSION Both pharmacologic vasodilation and graded hemorrhage induced PPV amplification similar to that observed in hypovolemia, reinforcing the idea that amplified arterial pressure variation does not necessarily represent hypovolemic status but rather potential cardiovascular responsiveness to fluid infusion.
منابع مشابه
Heart-lung interactions.
PURPOSE OF REVIEW Assessment of cardiovascular stability using ventilation-induced changes in measured physiological variables, referred to as functional hemodynamic monitoring, usually requires measurement of ventilation-induced changes in venous return. Thus, it is important to understand the determinants of these complex heart-lung interactions. RECENT FINDINGS Several animal and human stu...
متن کاملCorrection of hypovolemic hypotension by centrally administered naloxone in conscious rabbits.
Our goal was to test directly whether the vasoconstrictor action of naloxone during hypovolemic hypotension is centrally mediated. In eight chronically instrumented rabbits, progressive central hypovolemia and fall in cardiac output (CO) were produced by gradually inflating a cuff on the thoracic vena cava. Central hypovolemia was then sustained for 8 min by holding CO constant. In the main exp...
متن کاملVital Sign Prediction of Adverse Maternal Outcomes in Women with Hypovolemic Shock: The Role of Shock Index.
OBJECTIVE To determine the optimal vital sign predictor of adverse maternal outcomes in women with hypovolemic shock secondary to obstetric hemorrhage and to develop thresholds for referral/intensive monitoring and need for urgent intervention to inform a vital sign alert device for low-resource settings. STUDY DESIGN We conducted secondary analyses of a dataset of pregnant/postpartum women w...
متن کاملAcute elevation of plasma non-esterified fatty acids increases pulse wave velocity and induces peripheral vasodilation in humans in vivo.
Plasma NEFA (non-esterified fatty acid) concentrations are elevated in patients with obesity. In the present study we first aimed to provide an integral haemodynamic profile of elevated plasma NEFAs by the simultaneous assessment of blood pressure, pulse wave velocity, FBF (forearm blood flow) and sympathetic nervous system activity during acute elevation of NEFAs. Secondly, we hypothesized tha...
متن کاملOphthalmic pulse studies. I. Influence of intraocular pressure.
The relationship of the ophthalmic pulse amplitude to the intraocular pressure has been described in rabbits and dogs. The effect of a suction cup on the intraocular pressure has been investigated in rabbit eyes and human eyes. Sample pulse tracings have been obtained using a suction cup on rabbits and man. Two estimates were made of the volume changes associated with the ophthalmic pulse xoave...
متن کامل