Partial Quality Assessment of 60Co-Teletherapy Machine Performance
نویسنده
چکیده
The aim of this study was to assess the performance of 60Co-teletherapy unit at Radiation and Isotopes Center in Khartoum, using the common tools used for quality control (Front pointer, Graphic paper, Pin, Non-screen film, meter and Check plate). The collected and analyzed data revealed that: there was a difference between the calculated theoretical field size (FS) and the measured one relative to the change of SSD; and the average FS shift was 0.9 cm relative to the standard one, while the machine isocenter was almost fixed at 0 ̊ with a shift of 0.003 cm, which was within the standard limit (0.2 cm). The diaphragm isocenter showed a shift of ±0.36 cm (i.e. in clock and anti clock wise) in average relative to standard limit (±0.3 cm) and the couch vertical isocenter (CVI) relative to the SSD changes was exceeded the standard limit (0.2 cm) by a factor of 0.9 cm. Also the SSD determined by the optical distance indicator was greater than the actual SSD (determined by Front pointer and measured by scale meter) by an average of 0.8 cm; which exceeded the limit (0.3 cm) by an average factor of 0.5 cm. The study also showed that the penumbra profile (1.5 cm) was less than the actual specified for 60Co-teletherapy machine, while the radiation beam was so homogeneous across the field size.
منابع مشابه
Assessment of the effects of radiation type and energy on the calibration of TLD-100
Introduction: In radiation therapy, knowing the dose rates to healthy organs and tumors is beneficial, and thermoluminescent dosimeter (TLD) allows for this possibility. This study was aimed at determining the dose-response differences of TLDs in various types of radiation, energy levels, and dose rate calibrated with other types of radiation beams and energy and dose levels. Materials and Meth...
متن کاملDevelopment of Indigenous Source of Cobalt Suitable for Radiation Technology Applications
The role of Cobalt-60 as a radiation source in teletherapy for the treatment of cancer needs hardly to be reiterated. Although not used commonly in developed countries, cobalt-60 teletherapy machines can still be regarded as a very viable and cost effective option for the treatment of a sizeable fraction of cancer patients. At present in India, there are only 399 teletherapy units (280 telecoba...
متن کاملDose measurement of cobalt-60 radiotherapy beams in treatment fields.
BACKGROUND Radiation-therapy is a complex process with multiple steps, each of which has an impact on the quality of treatment. Accurate dosimetry is a critical step during the radiotherapy of cancer patients.The aim of the present study was to measure and evaluate the doses of two cobalt- 60 (60Co) teletherapy units GWXJ80 of NPIC China and Theratron 780 of AECL Canada at various points within...
متن کاملA Machine Learning Approach to No-Reference Objective Video Quality Assessment for High Definition Resources
The video quality assessment must be adapted to the human visual system, which is why researchers have performed subjective viewing experiments in order to obtain the conditions of encoding of video systems to provide the best quality to the user. The objective of this study is to assess the video quality using image features extraction without using reference video. RMSE values and processing ...
متن کاملQuality control of blood irradiation with a teletherapy unit: damage to stored red blood cells after cobalt-60 gamma irradiation.
BACKGROUND Previous publications have documented the damage caused to red blood cells (RBCs) irradiated with X-rays produced by a linear accelerator and with gamma rays derived from a 137Cs source. The biologic effects on RBCs of gamma rays from a 60Co source, however, have not been characterized. STUDY DESIGN AND METHODS This study investigated the effect of 3000 and 4000 cGy on the in vitro...
متن کامل