Transcatheter aortic valve implantation using the ACURATE TA™ system: 1-year outcomes and comparison of 500 patients from the SAVI registries

نویسندگان

  • Jochen Börgermann
  • David M. Holzhey
  • Matthias Thielmann
  • Evaldas Girdauskas
  • Holger Schroefel
  • Steffen Hofmann
  • Hendrik Treede
  • Klaus Matschke
  • Michael Hilker
  • Justus T. Strauch
  • Thierry Carrel
  • Thorsten Wahlers
  • Anno Diegeler
  • Jörg Kempfert
  • Thomas Walther
چکیده

OBJECTIVES The ACURATE TA TM system is a self-expanding transcatheter heart valve system designed for transapical access which has been proven to be safe and effective in the controlled setting of clinical trials. The SAVI-1 and SAVI-2 registries aimed to assess whether these promising outcomes can be translated into all-comers clinical routine. METHODS From November 2011 to 2012 (SAVI-1), and November 2013 to 2014 (SAVI-2), a total of 500 patients were enrolled in the prospective, all-comers, multicentre, multinational SAVI registries. Patients were treated according to the standard of care at their respective hospitals. We report and compare 30-day and 1-year clinical outcomes between SAVI-1 and -2. RESULTS Patients were 80.8 ± 6.1 years old, the mean logistic EuroSCORE-I was 23.4 ± 14.3%. Valves were deployed under rapid pacing in 71.3% of the procedures in SAVI-1, and in 3.6% in SAVI-2. There was no relevant difference in clinical and echocardiographic outcomes between SAVI-1 and SAVI-2. Overall mortality at 30 days and 1 year was 6.8% and 19.9%, the stroke rate was 2.2% and 3.7%, respectively; 10.2% of patients had received a permanent pacemaker, and no transcatheter valve-related complications after discharge were observed. Paravalvular leakage ≥2+ was reported in 1.9% of the patients at the early follow-up, and in 2.6% at the 1-year follow-up. CONCLUSIONS The SAVI-registries have confirmed that transapical implantation using the ACURATE TA TM device is safe and effective in an all-comers setting with low complication rates and stable performance outcomes at short-term and 1 year; outcomes were similar between SAVI-1 and -2.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of two valve systems for transapical aortic valve implantation: a propensity score-matched analysis.

OBJECTIVES Several alternative transapical (TA) aortic prostheses for aortic valve implantation (AVI) have recently become available. Data directly comparing the performance of these different TA-AVI valves, however, are sparse. Therefore, we sought to analyse the performance of the better-established balloon-expandable SAPIEN XT™ valve system, and compare it with the recently approved self-exp...

متن کامل

Transapical aortic valve implantation using a new self-expandable bioprosthesis (ACURATE TA™): 6-month outcomes.

OBJECTIVES The ACURATE TA(™) Aortic Bioprosthesis and Delivery System (Symetis S.A., Ecublens, Switzerland) is a new transcatheter aortic valve designed for transapical implantation. The six-month results from the completed first-in-man study are reported. METHODS The Symetis ACURATE TA(™) is composed of a porcine biological tissue valve attached to a self-expandable nitinol stent. It allows ...

متن کامل

Transapical aortic valve implantation using a Symetis Acurate self-expandable bioprosthesis: initial outcomes of 10 patients

INTRODUCTION Transapical aortic valve implantation (TA-AVI) has been widely introduced for treatment of patients with severe aortic stenosis in the last decade. Here we report our first clinical experience with 10 patients using the second-generation transapical Symetis Acurate TA aortic valve designed for transapical implantation. AIM To evaluate the results of transapical access in transcat...

متن کامل

The Self-Expanding Symetis Acurate Does Not Increase Cerebral Microembolic Load When Compared to the Balloon-Expandable Edwards Sapien Prosthesis: A Transcranial Doppler Study in Patients Undergoing Transapical Aortic Valve Implantation

OBJECTIVES The aim of this study was to quantify potential differences in count, frequency and pattern of high-intensity transient signals (HITS) during transapical transcatheter aortic valve implantation (TA-TAVI), by comparing the Symetis Acurate TA (SA) with the balloon-expandable Edwards Sapien XT (ES) system. BACKGROUND Recently, the Symetis Acurate TA revalving system has been introduce...

متن کامل

Transapical aortic valve implantation in patients with previous cardiac surgery.

BACKGROUND This study compared surgical outcomes of patients with previous cardiac surgery undergoing transapical transcatheter aortic valve implantation (PCS-TA-TAVI) with those of patients undergoing transapical transcatheter aortic valve implantation as an initial procedure (initial TA-TAVI) by using propensity analysis. METHODS From January 2005 through January 2013, 267 consecutive high-...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 51  شماره 

صفحات  -

تاریخ انتشار 2017