Evaluation of compression generated by self compressing Orthofix bone pins and lag screws in simulated lateral humeral condylar fractures.
نویسندگان
چکیده
A simulated lateral humeral condylar fracture was created in each of the 52 humeri collected from 26 dogs. One humerus from each pair was stabilized with a 2.0 mm cortical bone screw which was inserted in lag fashion. The other humerus from each pair was stabilized with a 2.2 mm threaded diameter Orthofix pin inserted across the condyle. Prior to each repair, an antirotational K-wire was placed and then the Pressurex Sensitive film was inserted in the osteotomy site in order to determine the compressive pressure (MPa), compressive force (KN), and area of compression (cm(2)) achieved during fixation. The maximum insertional torque achieved before stripping was measured for each implant. The mean compression generated by insertion of a 2.0 mm lag screw was 20.36 +/- 1.51 MPa compared to 18.88 +/- 1.76 MPa generated by a 2.2 mm Orthofix pin (p < 0.003). The mean area of compression generated by insertion of a 2.0 mm lag screw was 2.39 +/- 1.29 cm(2), compared to 1.16 +/- 0.84 cm(2) generated by insertion of a 2.2 mm Orthofix pin (p < 0.0001). The mean compressive force (compression x area compressed) generated by insertion of a 2.0 mm lag screw was 4.96 +/- 2.90 Kn, compared to 2.20 +/- 1.65 Kn generated by insertion of a 2.2 mm Orthofix pin (p < 0.0001). The mean insertion torque to failure for the lag screws was 0.49 +/- 0.07 NM, compared to 0.91 NM +/- 0.18 NM generated by the Orthofix pins (P < 0.0001). Both repair methods are likely to be acceptable for the repair of similar fractures in small breed dogs.
منابع مشابه
In vitro biomechanical comparison of three methods for internal fixation of femoral neck fractures in dogs.
The in vitro biomechanical properties of three methods for internal fixation of femoral neck fractures were evaluated. Fifty cadaveric femura from Beagle dogs were used. Ten intact femora served as controls. In 40 femura, an osteotomy of the femoral neck was performed to simulate a transverse fracture. With the remaining 30 femura, three repair methods (two medium Orthofix pins, a 2.7 mm cort...
متن کاملA Pitfall in Fixation of Distal Humeral Fractures with Pre-Contoured Locking Compression Plate
Anatomically precontoured locking plates are intended to facilitate the fixation of articular fractures and particularly those associated with osteoporosis. Fractures of the distal humerus are relatively uncommon injuries where operative intervention can be exceptionally challenging. The distal humeral trochlea provides a very narrow anatomical window through which to pass a fixed-angle locking...
متن کاملHydroxyapatite coating of threaded pins enhances fixation.
We measured the insertion and extraction torque forces in a randomised study of 76 external fixation screws in 19 patients treated by hemicallotasis for osteoarthritis of the medial side of the knee. The patients were randomised to have either standard tapered screws (Orthofix 6/5 mm) or the same screws with hydroxyapatite (HA) coating. One patient had two standard and two HA-coated screws. All...
متن کاملمقایسه اختلاف میزان حرکت آرنج در دو روش جراحی جانبی و خلفی برای درمان شکستگی های سوپراکوندیلار نوع سوم بازو
Introduction & Objective: Supra condylar humeral fractures are frequent in children at 5-8 years old and its neurovascular complications are more than other fractures. Treatment of displaced fractures (type3) is surgical with open reduction and internal fixation, through posterior, medial, lateral or anterior approach. This study is performed for comparison of the effect of posterior or lateral...
متن کاملBiomechanical Evaluation of Interfragmentary Compression At Tibia Plateau Fractures In Vitro Using Different Fixation Techniques
Reliable osteosynthesis of intraarticular fractures depends on lasting interfragmentary compression. Its amount differs in the applied fixation method. The interfragmentary compression of cancellous and cortical lag screws and angle stable locking plates was quantified in an osteoporotic and non-osteoporotic synthetic human bone model.A split fracture of the lateral tibia plateau (AO/OTA type 4...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Veterinary and comparative orthopaedics and traumatology : V.C.O.T
دوره 20 3 شماره
صفحات -
تاریخ انتشار 2007