Contouring Left Ventricle From Echocardiographic Image Sequence In Long-Axis View
نویسندگان
چکیده
In this paper we suggest an approach to a completely automatic contouring the left ventricle (LV). We use the method of signatures to describe the shape of the contour. Analysis of contours performed manually enables us to conclude that the signature of any contour of any patient has the shape of the inverted letter "M". This allows reducing the contouring problem to the problem of signature reconstruction. So, the task is transferred from a twodimensional space in a one-dimensional. Algorithm of semiautomatic contouring based on the known first frame contours is described. So, it is obvious that the problem of completely automatic contouring demands to select the contour on the first frame automatically. Solution of this problem is to restore the signature with the correct shape in the form of the inverted letter "M" and we offer a way to do it.
منابع مشابه
Assessment of left ventricular torsion in long axis view in patients with chronic stenosis of coronary arteries
Background: Left ventricular torsion is one of the most important biomechanical parameters of heart that routinely is measured in short axis view. A review of the literature has indicated that assessment of left ventricular torsion in short axis view has some limitations. In the present study, we evaluated whether torsion angle assessment in long axis view can be used as a diagnostic biomechan...
متن کاملStudy of the Mass Center Motion of the Left Ventricle Area in Echocardiographic Videos
The study of the mass center (CM) motion of the left ventricle (LV) area in echocardiographic videos is presented. CM of any phase of the cardiac cycle is inside an ellipse. An area of the ellipse is not more than 2% of the area of LV in systole. The criterion to identify correct and incorrect forms of contours are proposed for automatic contouring of LV in the frames of a video sequence.
متن کاملCross sectional echocardiographic assessment of left ventricular volume and ejection fraction in patients with tetralogy of Fallot. Comparison with biplane angiographic measurements.
To evaluate the usefulness and accuracy of calculating left ventricular volume and ejection fraction from cross sectional echocardiograms in patients with tetralogy of Fallot, 28 patients were studied within 24 hours of cineangiography. Indexed end diastolic and end systolic volumes were calculated from three different paired echocardiographic projections: (a) the two and four chamber views fro...
متن کاملEndocardial Border Detection Using Radial Search and Domain Knowledge
The ejection fraction rate is a frequently used parameter when treating patients who suffered from heart disease. However, the measurement of this ejection rate depends on manual segmentation of left ventricle cavity in the end-systolic and end-diastolic phases. This paper proposes a semi-automatic algorithm for the detection of left ventricular border in two dimensional long axis ultrasound ec...
متن کاملReference values of M-mode echocardiographic parameters and indices in conscious Labrador Retriever dogs
Breed-wise standard echocardiographic values in dogs have been reported as there is variation in body and chest conformation which limits the application of data of one breed for other breed. Labrador Retrievers being originated from hunting dogs, might have different echocardiographic values from standard normal range of other dog breeds. So, the present study was aimed to determine the M-mode...
متن کامل