Microscope-controlled glass bead blasting: a new technique

نویسندگان

  • Peter Kotschy
  • Sascha Virnik
  • Doris Christ
  • Alexander Gaggl
چکیده

OBJECTIVE The aim of periodontal therapy is the healing of periodontal inflammation; the protection of the attachment and the alveolar bone; and the regeneration of the periodontal structures. In the therapy of periodontitis, supra- and subgingival scaling and root planing plays a main role. The procedure described combines perfect root cleaning without scaling and root planing and minimal invasive periodontal surgery without a scalpel. MATERIAL AND METHODS Glass beads of 90 μm were used with the kinetic preparation unit PrepStart(®) under a pressure of 0.5-5 bar. This technique was practised only under visual control using the OPMI(®) PRO Magis microscope. Seven examinations were carried out at baseline after 3, 6, 12, 18, 24, and 36 months. RESULTS Time shows a statistically significant influence on all of the considered target variables (P < 0.0001 for all). As the according estimate is negative, probing depth decreases over time. The major decrease seems to be during the first 6 months. Considering probing depth, plaque on the main effect root shows significant influence (again, P < 0.0001 for all). Observations with high probing depth at the beginning were faster than those with low probing depth. The same characteristic appears by attachment level. Patients with more loss of attachment show more gain. CONCLUSIONS Using microscope-controlled glass bead blasting results in a perfectly clean root surface using visual control (magnification 20×). Microscope-controlled glass bead blasting is therefore a good alternative to periodontal surgery.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Magnetically and biologically active bead-patterned hydrogels.

We present a new approach to the direct patterning of biologically and magnetically active microbeads in nonbiofouling polymer scaffolds for use in microfluidic devices. Briefly, the process involves treatment of a glass substrate, conformal contact bonding of a PDMS microchannel on the substrate, filling of the channel with beads and prepolymer solution, and UV-initiated photopolymerization of...

متن کامل

An Experimental Study on the Fabrication of Glass-based Acceleration Sensor Body Using Micro Powder Blasting Method

This study investigated the feasibility of the micro powder blasting technique for the micro fabrication of sensor structures using the Pyrex glass to replace the existing silicon-based acceleration sensor fabrication processes. As the preliminary experiments, the effects of the blasting pressure, the mass flow rate of abrasive and the number of nozzle scanning times on erosion depth of the Pyr...

متن کامل

Laser Doppler velocimetry of basilar membrane vibration.

A method is described for the measurement of basilar membrane (BM) vibration velocimeter (LDV). The instrumentation was coupled to a compound microscope which served to visualize reflective glass microbeads placed on the BM. The laser beam of the LDV was focused in the microscope object plane and positioned over the reflective bead. We show examples of frequency tuning curves and displacement i...

متن کامل

Evaluation of new technique of sterilization using biological indicator

Background A novel technique of sterilization of endodontic files is introduced in this article. Aims Newly introduced sterilization unit, named "SteriFast" is compared with autoclave and glass bead sterilizer using biological indicator. Materials and Methods Spore strips of Bacillus pumilus were cultured in nutrient broth. This cultured media was used to contaminate the experimental sample...

متن کامل

Screening small-molecule compound microarrays for protein ligands without fluorescence labeling with a high-throughput scanning microscope.

We describe a high-throughput scanning optical microscope for detecting small-molecule compound microarrays on functionalized glass slides. It is based on measurements of oblique-incidence reflectivity difference and employs a combination of a y-scan galvometer mirror and an x-scan translation stage with an effective field of view of 2 cm x 4 cm. Such a field of view can accommodate a printed s...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 3  شماره 

صفحات  -

تاریخ انتشار 2011