Correlation between Reflux and multichannel intraluminal impedance pH monitoring in untreated volunteers.
نویسندگان
چکیده
OBJECTIVES/HYPOTHESIS Although probable causative agents have been identified (e.g., refluxate components, tobacco smoke), the definitive mechanism for inflammation-related laryngeal mucosal damage remains elusive. Multichannel intraluminal impedance combined with pH monitoring (MII/pH) has emerged as a sensitive tool for diagnosis and characterization of gastroesophageal reflux disease with laryngopharyngeal manifestations. To determine the relationship between laryngeal signs and MII/pH, we examined correlations between Reflux Finding Score (RFS) ratings of videostroboscopic laryngeal examinations and findings from MII/pH. STUDY DESIGN Correlational study. METHODS Healthy, untreated volunteers (n = 142) underwent reflux diagnosis using data acquired from MII/pH testing. Eight trained clinicians performed RFS ratings of corresponding laryngeal examinations. Averaged RFS ratings were compared to MII/pH data using Pearson correlation coefficients. The relationship between RFS and MII/pH findings and demographic/clinical information (age, sex, smoking status, reflux) was assessed using general linear modeling. Rater reliability was evaluated. RESULTS Posterior commissure hypertrophy was negatively correlated with minutes of nonacid refluxate (R = -0.21, P = .0115). General linear modeling revealed that 28% to 40% of the variance in ratings of ventricular obliteration, erythema/hyperemia, vocal fold edema, diffuse laryngeal edema, posterior commissure hypertrophy, and granulation/granuloma could be explained by main and interaction effects of age, sex, smoking status, and reflux. Intra- and inter-rater reliability for RFS were poor-fair. CONCLUSIONS These results support the theory that the RFS is not specific for reflux in healthy, untreated volunteers, suggesting there may be alternate explanations for inflammatory clinical signs commonly ascribed to reflux in this population.
منابع مشابه
Correlation of Gastroesophageal reflux disease Assessment Symptom Questionnaire to impedance-pH measurements in children
Background Esophageal multichannel intraluminal impedance-pH monitoring has become one of the preferred tests to correlate observed reflux-like behaviors with esophageal reflux events. The Gastroesophageal reflux disease Assessment Symptom Questionnaire is a validated tool used to distinguish infants with gastroesophageal reflux disease from healthy children. The aim of this study was to determ...
متن کاملGastroesophageal reflux evaluation in patients affected by chronic cough: Restech versus multichannel intraluminal impedance/pH metry.
OBJECTIVES/HYPOTHESIS Oropharyngeal (OP) pH monitoring has been developed to detect supra-esophageal gastric reflux (SEGR). The results obtained with OP pH-metry and multichannel intraluminal impedance/pH monitoring (MII/pH) were compared. STUDY DESIGN Diagnostic study. METHODS Ten patients (age 46.33 ± 9.86 years) presenting with chronic coughing underwent simultaneous OP and MII/pH record...
متن کاملEsophageal Multichannel Intraluminal Impedance and pH Monitoring in the Evaluation of Achalasia and Gastroesophageal Reflux Disease in a Child with Down Syndrome: a Case Report.
We report the case of a rare association between achalasia and Down syndrome in a child presenting with symptoms that suggest a gastroesophageal reflux. Evaluation of the patient with 24-hour multichannel intraluminal impedance and pH recording and upper endoscopy lead to the diagnosis of achalasia. However, the persistence of the symptoms after the concurrent surgical myomectomy and fundoplica...
متن کاملComparison of multichannel intraluminal impedance-pH monitoring and reflux scintigraphy in pediatric patients with suspected gastroesophageal reflux
AIM To evaluate the agreement of multichannel intraluminal impedance-pH monitoring (MII-pHM) and gastroesophageal reflux scintigraphy (GES) for the diagnosis of gastroesophageal reflux disease. METHODS Seventy-five consecutive patients with suspected gastroesophageal reflux disease (GERD) underwent 24-h combined MII-pHM recording and one hour radionuclide scintigraphy during the course of the...
متن کاملClinical Applications of Esophageal Multichannel Intraluminal Impedance Testing.
Multichannel intraluminal impedance is a relatively new technology that allows detection of bolus movement in the gastrointestinal tract without the use of radiation. In clinical applications it is combined with manometry, allowing a better evaluation of the functional characteristics (ie, bolus transit) of esophageal motility abnormalities. When combined with pH monitoring, it provides more co...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Laryngoscope
دوره 124 10 شماره
صفحات -
تاریخ انتشار 2014