Evaluation of management of tibial non-union defect with Ilizarov fixator.
نویسندگان
چکیده
BACKGROUND Tibial bone defect lead to limb shortening and functional deficit and needs proper treatment. There are various treatment modalities for bone defect in long bone to restore length and function of the limb, i.e. bone grafting, vascularised bone graft, allograft and bone transport. Bone transport can be done through fixators (uniplaner or ring) and intramedullary nail system. This study was conducted on management of tibial non-union with Ilizarov external fixator. METHOD This descriptive study was performed on 58 patients in Agency Headquarter Hospital, Bajawar and Lady Reading Hospital, Peshawar, from January 2000 to January 2006. Patients of either gender with age between 9 to 58 years, having nonunion (clean and infected nonunion) in tibia with defect of 2 to 7cm due to trauma or firearm injury were included in the study. These patients were followed up upto one year. Outcome measures were according to the classification of Association for the Study and Application of the Method of Ilizarov (ASAMI), which is based on radiological (defect filling) and clinical (functional) findings. RESULTS Out of 58 patients, 44 (75%) were male and 14 (25%) were female. Mean age was 30 years (9 to 58 years). 38 (65.52%) patients had infected non-union while 20 (34.48%) had clean non-union. Right tibia was involved in 32 patients (51.17%) and left was involved in 26 (44.83%) patients. The cause of initial trauma was road traffic accident in 27 patients (46.55%), firearm injury in 23 patients (39.65%) and a simple fall in 8 patients (13.79%). The length of average bone defect was 2.90 cm (200-7.00 cm). Radiological results were excellent in 33 (58.89%) patients, good in 12 (20.68%) patients, fair in 8 (13.79%) patients and poor in 5 (8.62%) patients. The clinical results were excellent in 33 patients (56.89%), good in 18 patients (31.05%), fair in 4 (6.89%) patients and poor in 3 patients (5.17%). CONCLUSION Ilizarov ring fixator is excellent treatment modality for tibial non-union with a defect, regarding bone union, deformity correction, infection eradication, limb length achievement and limb function but this needs prolonged learning curve for fresh orthopedic surgeons.
منابع مشابه
Ilizarov Versus AO External Fixator for the Treatment of Tibia Open Fractures
BACKGROUND In developing countries, Ilizarov or AO external fixator is usually used for treatment of tibial open fractures. The purpose of this study was to compare the efficacy of these two methods for treatment of tibial open fractures. METHODS From April 2002 to April 2010, 120 patients with open tibial fractures admitted to the Department of Orthopedics of Babol University of Medical Scie...
متن کاملIlizarov ring fixator in the management of infected non-unions of tibia
PURPOSE The purpose of the study was to evaluate the effectiveness of debridement and application of Ilizarov ring fixator (IRF) in the management of infected tibial non-unions. PATIENTS AND METHODS Twenty six patients with infected non-unions of tibia were managed by debridement and resection of infected portion ± partial fibulectomy and stabilization by Ilizarov ring fixator. Bone segment t...
متن کاملThe treatment of high tibial osteotomy non-union with the Ilizarov external fixator
To evaluate the results of the Ilizarov external fixator in the treatment of non-union post-high tibial osteotomy (HTO). Five non-unions, in four patients, following HTO were treated by Ilizarov fixation. Clinical outcome was assessed pre- and post-operatively by the Knee Society Clinical Rating System (KSCRS). Radiological analysis assessed bone healing pre- and post-operatively and measured p...
متن کاملTreatment of Open Tibial Fractures: Convert-ing or Continuing External Fixation?
Background: The treatment of open tibial fractures is still an orthopaedic challenge and full of complications. In many cases the use of external fixator that has been known as a non-union machine is obligatory with a high incidence of pin track infection and other complications. The aim of this study was to compare the use of external fixation as a definite method for treatment of open tibial ...
متن کاملTreatment of congenital pseudarthrosis of the tibia with the Ilizarov technique. Case report and review of the literature.
Congenital pseudarthrosis of the tibia continues to pose one of the most difficult problems in paediatric orthopaedic surgery. The surgical procedures most used for treating congenital pseudarthrosis of the tibia are intramedullary nailing associated with bone grafting, vascularized fibular graft and the Ilizarov external circular fixator. Even when union is achieved, the residual deformities i...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of Ayub Medical College, Abbottabad : JAMC
دوره 19 3 شماره
صفحات -
تاریخ انتشار 2007