Simulation of polyethylene wear in ankle joint prostheses.

نویسندگان

  • Carol J Bell
  • John Fisher
چکیده

The performance of total ankle replacements (TARs) have not been comparable to those of the other major joints of the lower extremity. The aim of this work was to develop a new simulator test to compare the wear of a new mobile bearing TAR (Mobility) with one with a good clinical history, the Buechel Pappas, using kinematic inputs derived from the literature. The wear rate for the Mobility components was lower than that for the Buechel-Pappas ankle joints at all time points. The wear rate for both sets of components increased with the inclusion of an anterior/posterior displacement in the kinematic inputs. This was expected as the components are subjected to higher kinematic demands and reproduces similar effects found in knee prostheses. This study has demonstrated that it is possible to study wear of TARs in a modified simulator originally designed for total knee replacements. It was also shown that the new Mobility ankle compares favorably with the Buechel Pappas ankle, which has a successful clinical history, under the simulator test conditions described.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Wear Distribution Detection of Knee Joint Prostheses by Means of 3D Optical Scanners

The objective of this study was to examine total knee polyethylene inserts from in vitro simulation to evaluate and display-using a 3D optical scanner-wear patterns and wear rates of inserts exposed to wear by means of simulators. Various sets of tibial inserts have been reconstructed by using optical scanners. With this in mind, the wear behavior of fixed and mobile bearing polyethylene knee c...

متن کامل

Comparison of polyethylene wear in anatomical and reversed shoulder prostheses.

Wear of polyethylene is associated with aseptic loosening of orthopaedic implants and has been observed in hip and knee prostheses and anatomical implants for the shoulder. The reversed shoulder prostheses have not been assessed as yet. We investigated the volumetric polyethylene wear of the reversed and anatomical Aequalis shoulder prostheses using a mathematical musculoskeletal model. Movemen...

متن کامل

Polyethylene Wear in Anatomic and Reversed Shoulder Prostheses

INTRODUCTION: Polyethylene wear is a recurrent problem in joint arthroplasty. In addition to permanent deformation or complete destruction of the component, small debris particles are also associated to inflammation reaction of the surrounding bone, eventually leading to the failure of the bound between the implant and the host bone, and implant loosening. In anatomic total shoulder arthroplast...

متن کامل

Wear simulation of total hip prostheses with polyethylene against CoCr, alumina and diamond-like carbon.

The wear of ultra-high molecular weight polyethylene acetabular cups was studied with a new biaxial hip wear simulator using diluted calf serum as a lubricant. The cups had been packed and gamma-irradiated in argon. The cups were articulated against two established types of femoral head, alumina and CoCr, and one experimental type, CoCr coated with diamond-like carbon (DLC). The diameter of the...

متن کامل

Femoral component wear in retrieved hip prostheses.

We retrieved 159 femoral heads at revision surgery to determine changes in surface configuration. Macroscopic wear of the head was observed in three bipolar hip prostheses as a result of three-body wear. There was a considerable change in surface roughness in the internal articulation of bipolar hip prostheses. Roughness in alumina heads was almost the same as that in new cobalt-chromium heads....

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of biomedical materials research. Part B, Applied biomaterials

دوره 81 1  شماره 

صفحات  -

تاریخ انتشار 2007