Determination of Acquisition Frequency for Intrafractional Motion of Pancreas in CyberKnife Radiotherapy

نویسندگان

  • Huailing Zhang
  • Guoru Zhao
  • David Djajaputra
  • Yaoqin Xie
چکیده

PURPOSE To report the characteristics of pancreas motion as tracked using implanted fiducials during radiotherapy treatments with CyberKnife. METHODS AND MATERIALS Twenty-nine patients with pancreas cancer treated using CyberKnife system were retrospectively selected for this study. During the treatment, the deviation is examined every 3-4 nodes (~45 s interval) and compensated by the robot. The pancreas displacement calculated from X-ray images acquired within the time interval between two consecutive couch motions constitute a data set. RESULTS A total of 498 data sets and 4302 time stamps of X-ray images were analyzed in this study. The average duration for each data set is 634 s. The location of the pancreas becomes more dispersed as the time elapses. The acquisition frequency depends on the prespecified movement distance threshold of pancreas. If the threshold between two consecutive images is 1 mm, the acquisition frequency should be less than 30 s, while if the threshold is 2 mm, the acquisition frequency can be around 1 min. CONCLUSIONS The pancreas target moves significantly and unpredictably during treatment. Effective means of compensating the intrafractional movement is critical to ensure adequate dose coverage of the tumor target.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quantifying variability of intrafractional target motion in stereotactic body radiotherapy for lung cancers

In lung stereotactic body radiotherapy (SBRT), variability of intrafractional target motion can negate the potential benefits of four-dimensional (4D) treatment planning that aims to account for the dosimetric impacts of organ motion. This study used tumor motion data obtained from CyberKnife SBRT treatments to quantify the reproducibility of probability motion function (pmf) of 37 lung tumors....

متن کامل

Impact of Intrafractional Prostate Motion on the Accuracy and Efficiency of Prostate Cancer Treatment on CyberKnife Radiotherapy

One of the most common treatments for men with localized prostate cancer is radiation therapy, which involves delivering small doses of radiation to the prostate for an extended period of time. Stereotactic-body radiation therapy (SBRT) is a form of radiotherapy that delivers increased dosage to the prostate with more precision. The results are shorter treatment times, increased effectiveness, ...

متن کامل

Initial evaluation of intrafraction motion using frameless CyberKnife VSI system.

AIM To analyze intrafraction movement in patients undergoing frameless robotic radiosurgery and evaluate the influence of image acquisition frequency on global accuracy. BACKGROUND Stereotactic radiosurgery requires high spatial accuracy in dose delivery. In conventional radiosurgery, a rigid frame is used to guarantee a correct target alignment and no subsequent movement. Frameless radiosurg...

متن کامل

To frame or not to frame? Cone‐beam CT‐based analysis of head immobilization devices specific to linac‐based stereotactic radiosurgery and radiotherapy

PURPOSE Noninvasive frameless systems are increasingly being utilized for head immobilization in stereotactic radiosurgery (SRS). Knowing the head positioning reproducibility of frameless systems and their respective ability to limit intrafractional head motion is important in order to safely perform SRS. The purpose of this study was to evaluate and compare the intrafractional head motion of a...

متن کامل

A study on the accuracy of motion tracking of thoracic tumors at radiotherapy with external surrogates

Introduction: In radiotherapy with external surrogates, exact information of tumor position is one of the key factors that improves treatment delivery. Many dynamic tumors in thorax region of patient move mainly due to respiration and are known as intra-fractional motion error that must be compensated, as well. One of clinical strategy is using Stereotactic Body Radiation Thera...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 2014  شماره 

صفحات  -

تاریخ انتشار 2014